Set Up the Campus-REX System
3-30
Campus-REX RS Interface Card User Manual
Using the LCD
To set the Timing Source from the LCD:
1
Press Escape until
Campus RS I/F: REX
displays.
2
Press Next twice, until
DATA PORT CONFIG & STATUS
displays,
then press Enter. The LCD displays
CONFIGURE REX SETTINGS
.
3
Press Enter. The LCD displays
REX MODE
.
4
Press Next until
TIMING SOURCE
displays, then press Enter. The
LCD displays the current Timing Source setting.
5
Press Next until the desired Timing Source setting displays, then press
Enter. The LCD displays the new Timing Source setting.
Using an ASCII Terminal
To set the Timing Source from an ASCII terminal:
1
Connect the ASCII terminal and log on to the Main Menu. See
an ASCII Terminal” on page 3-2
for instructions.
2
From the Main Menu, type
then press
. The Data Port Settings
menu displays.
2
ENTER
Dec 9, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:16:44
Local Unit ID:
Campus-REX Unit #34
Local I/F:
REX
Remote Unit ID: Campus-REX Unit #12
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
DATA PORT SETTINGS
MAC ADDRESS:
00:20:A7:21:2F:6B
10 BASE-T STATUS:
Up
1)
BRIDGE/ROUTER CONFIGURATION
2)
SNMP CONFIGURATION
3)
WRITE NVRAM
4)
RESET INTERFACE CARD
WARNING:
NVRAM must be written and interface card reset for any
configuration changes to take effect.
(R)eturn
ENTER CHOICE>
CAD1069i5.book Page 30 Thursday, May 30, 2002 7:32 AM