SPECIFICATIONS
Physical Characteristics
PS Chassis
Height:
7 inches
(17.78 cm)
Width:
19 inches
(48.3 cm)
Depth:
12 inches
(30.12 cm)
Environmental Conditions
Ambient Temperature:
Operating: +32
°
F to +122
°
F (0
°
C to +50
°
C)
Storage:
–40
°
F to +158
°
F (–40
°
C to +70
°
C)
Relative Humidity:
Operating: 10% to 80% noncondensing
Storage:
5% to 90% noncondensing
Power Requirements
PS Chassis:
+5 Vdc @ 3 amps
+12 Vdc @ 1 amp (switching)
3.1
DMPS-10 AC Power Supply
The DMPS-10 AC Power Supply provides all dc operating voltages and current required by up to
four fully-populated RDC-01 or RDC-02 chassis. The rack mounted power supply plugs directly
into a standard 110 Vac primary power source outlet. This power supply can also be set for use
with 240 Vac. The power supply comes equipped with one nine-conductor power cord and an AC
line cord. The DMPS-10 will power one PS assembly and can house up to three additional
DMPS-10 EXP expansion power modules to supply power for four PS chassis assemblies.