800-357-104-01, Revision 01
Installing Multiplexers
HMS-357 List 4 and List 5
September 29, 2000
35
HXU-3
5
7
Setting Up Basic HXU-357 System Parameters in the System Administration Menu
Step
Procedure
Installer Check
ü
ü
ü
ü
1
From the Shelf Status screen, press
to log onto the HXU-357.
For more information on navigating through the menu system, refer to the procedures detailed in
“Setting Up the Communications Channel through the HXU-357” on page 34
H
2
At the prompt (
ID:
), enter the password to access the HXU-357 Root Menu.
The default password is
public
.
H
3
Press
and then press
to select System Administration from the root menu of the Shelf
Status screen.
H
4
Press
and then press
to Change System Settings for the HXU-357, then select one of
the following setting options by entering its number and entering the appropriate data.
(The HMU-319 List 7A automatically sets the date and time parameters for the HXUs.
If using an HMU-319 List 7, set the HXU time and date parameters here to match those of the HMU.)
Date
Time
System name
System location
Contact person
Write Community Name
Read Community Name
H
5
Press
+
to return to the System Administration menu.
H
6
Press
and then press
to select Change IP Address (Multiplexer IP).
H
7
Enter the address and mask information (selections
through
)
established for your particular
addressing plan.
Set the IP address of the HXU-357
Set the trap IP address to the same address as previously set on the HMU
(refer to
“Setting the Local IP Address (Option A)” on page 31
Complete the 10BASE-T connection from the HXU-357 to the hub resident on the HMU
H
8
Press
+
to return to the root menu of the Shelf Status screen.
H
9
“Configuring DS1 Services through the HXU-357” on page 36
H
Installer Signature
?
?
?
?
Date
M
5
ENTER
2
ENTER
1
2
3
4
5
6
7
CTRL
P
3
ENTER
1
1 0
CTRL
R