Front Panels
LTPE-UG-1017-01 Issue 1
6
February 15, 2001
UTU-731 List 1 and UTU-732 List 1
Table 3.
Front-Panel LED Status Functions
LED
Mode
Description
SINC LED
Steady green
Slow flashing
Off
HDSL loop is ready to transmit
and receive data.
HDSL loop acquisition is in
progress.
HDSL loop is not configured.
ALM LED
Steady red
Pulsing red
Off
Indicates:
•
Loss of sync word (LOSW).
•
Margin is below the set
margin alarm threshold.
•
Errored Seconds (ES) count
is above threshold on any
span.
Pulses for every ES on any span.
Normal transmit or receive data
is in progress.
IF LED
Steady red
Indicates:
•
Loss of G.703 signal (LOS)
alarm.
•
Loss of Clock (LOC) alarm
due to loss of TT clock (Nx64k
timing).
•
Loss of external clock (LOC)
alarm (when using EXT
timing).
LOC and REM
loopback
LEDs
(a)
LOC
REM
Off
Off
No loopbacks are active.
Steady red
Off
Local HDSL analog loopback is
active.
Off
Steady red
Remote loopback is active.
Blinking red
Off
Local interface loopback is
active.
Blinking red
Blinking red A loopback away from the local
equipment is active.