C
ABINET
C
ONFIGURATION
The upper part of the Twin Tech cabinet may be equipped with:
−
Two Controller units,
−
or a Controller unit and a backup power supply module.
The Controller units, control all of the circuits (128 max.) constituting the modules available in the cabinet
(32 max.), according to the configuration recorded by the Unit software (patch) and the channel values
present on the DMX A, DMX B and ARTNET/sACN/RDM inputs
(ETHERNET connection).
3.1
S
YNCHRONIZATION
The human interface is synchronized continuously between two controllers (if present).
If two controllers are present, data from a controller (the one inserted into the slot from the top), with the
exception of the page "Diagnosis of the cabinet" or information from the selected controller using the tabs
"CTRL1" and "CTRL2".
If the controller 1 is a not functional, timing continues with the controller 2.
If the cabinet has only one controller all the information obtained from this controller
Note:
Only the controller in slot from the top is able to detect modules in the cabinet (see Chapter Power
Configuration) and to report the status of sinewave and thyristor modules with full diagnostic
option (see section "Module Measuring" and "Diagnostic Modules")