AGLAS Master Control Device
Modes of Operation
© ADB SAFEGATE All Rights Reserved
20
96A0480 Rev. B
2.7.2 Operating Mode
2.7.2.1 HMI Display Screen
Header:
The header is always displayed on every screen and shows the Master ID, Master Name, and a lightning bolt indicating if
the circuit is energized or not.
Footer:
The footer is always displayed on every screen and shows the current date/time, the version of the master firmware, and
the uptime of the master.
Backlight:
The backlight on the screen will turn off after 20 minutes of inactivity. To wake the screen up simply touch it. The
backlight will also turn on if a new master or circuit alarm is received. New warnings, master or circuit, will not turn the
backlight on.
2.7.2.2 Status Screen
The status screen gives detailed status information of the master. The upper left section details the power readings of the circuit
(watts, Amps, volt amps, volts). The upper right section shows the IP addresses of the two network interfaces. The bottom left
corner shows how many lamps are out on the circuit. The bottom center sections shows the master status, the status of the PTP
synchronization with other masters, and which network is currently being used. The bottom right corner shows the number and
type of connected clients
Controlling clients:
— M = Maintenance, F = Full Operational, P = Partial Operational
Monitoring clients:
— F = Full Monitoring, P = Partial Monitoring
Figure 9:
Status screen
Status Screen - No Current