4.5 Installing a fitting
Note
Never leave an installed base without a cover; always cover the base with an inset light unit or a suitable cover plate.
Steps
Image Examples
1.
Make sure that the inner surfaces of the base are clean
and dry.
2.
Place the gasket on the groove or the base/light unit to
seal the gap.
Note
The gasket should always be replaced with a new
one when a light unit is installed.
3.
Connect secondary plug(s) and its receptacle inside the
base. Check cable(s) lay correctly while inserting the light
unit.
4.
Use lifting hooks to lower the light into the base.
5.
Align the light to the base groove.
6.
Loosely fasten the light with bolts/lock nuts by hand.
7.
Fasten the bolts/lock nuts using a torque wrench,
gradually in sequence, to a torque of 40 Nm (bolts) and
35 Nm (studs).
Note
Do not use high speed for tightening, the
recommended speed is 10-40 rpm. It is also
recommended to use a suitable lubricant when
fastening the bolts (use nickel or graphite grease,
but NOT copper-based grease as it stimulates
corrosion).
Figure 20: LIGHT INSTALLATION
UM-0106, Rev. 1.0, 2019/12/19
25
Copyright
©
ADB Safegate, All Rights Reserved
Summary of Contents for RELIANCE Shallow Base
Page 2: ......
Page 6: ...RELIANCE Shallow Base TABLE OF CONTENTS vi Copyright ADB Safegate All Rights Reserved ...
Page 8: ...RELIANCE Shallow Base List of Figures viii Copyright ADB Safegate All Rights Reserved ...
Page 10: ...RELIANCE Shallow Base List of Tables x Copyright ADB Safegate All Rights Reserved ...
Page 16: ...RELIANCE Shallow Base Safety instructions 6 Copyright ADB Safegate All Rights Reserved ...
Page 22: ...RELIANCE Shallow Base Introduction 12 Copyright ADB Safegate All Rights Reserved ...
Page 36: ...RELIANCE Shallow Base Installation 26 Copyright ADB Safegate All Rights Reserved ...
Page 38: ...RELIANCE Shallow Base Maintenance 28 Copyright ADB Safegate All Rights Reserved ...
Page 42: ...RELIANCE Shallow Base Spare Parts 32 Copyright ADB Safegate All Rights Reserved ...
Page 46: ......