5.0 Operation
5.1 RELIANCE Intelligent Lighting
The RELIANCE Intelligent Lighting system is designed to provide individual control and monitoring of airfield lighting using
the series circuit as a means of communicating status information from airfield lights and sensors. The same concept is used
for lighting control providing the foundation for SMGCS or A-SMGCS, which includes for example automation of stop bars
with or without sensors, taxiway guidance (routing) in combination with status monitoring. For more information, see
RELIANCE Intelligent Lighting documentation.
5.2 RELIANCE IQ and the 2A concept
The RELIANCE Intelligent Lighting system, using the IQ products, is designed to provide selective switching and/or monitoring
of airfield lighting by use of an addressable switching unit inside each individually controlled light fixture. A RELIANCE IQ light
fixture is connected to the secondary side of a standard series circuit isolation transformer. Communications to/from a
RELIANCE IQ light fixture uses a unique power line communication technique developed by ADB SAFEGATE where the
communication signals are superimposed on the series circuit current.
In a 2A system the CCR is set at a constant 2A current and the RELIANCE Intelligent Lighting system manages the intensity
level of every single RELIANCE IQ light fixture. Furthermore, the RELIANCE IQ light fixtures could have different light intensity
levels in the same circuit.
5.3 Sensor Interface Unit (SIU)
Sensors for presence- and direction detection of aircraft and vehicles on the airfield can easily be interfaced to the RELIANCE
Intelligent Lighting system using an SIU. The SIU communicates the detect/no-detect status signals as well as its own status
to the series circuit in the same manner as the RELIANCE IQ. The SIU is also connected to the secondary side of a standard
isolation transformer using a standard 2-pin FAA-style connector. Connection to the sensor is established using an IP68 rated
7-pin connector. The SIU can also supply the sensor with DC-voltage from a built-in current to voltage converter.
5.4 Network Concentrator Unit (NCU)
The NCU concentrates all incoming status information from the field, both lamp and sensor statuses. The NCU includes
redundant capability.
5.5 Series Circuit Modem (SCM)
The SCM is an interface to the series circuit which receives command from an NCU. The SCM connects to the series circuit via
a standard isolation transformer and to an NCU via standard RS485 or RS232 serial communication.
5.6 Series Circuit Filter (SCF)
The SCF is connected across the Constant Current Regulator (CCR) series circuit output and is used to contain the
communication signaling within the airfield circuit and minimize feedback into the regulator.
5.7 Control System Interface
The NCU operates as RELIANCE Intelligent Lighting (IL) main interface interpreting commands sent from the Host/Supervisor
system and in turn controlling the appropriate RELIANCE IQ as directed. It maintains all lighting and error status, sensor
detection as reported from the airfield components and is the central point of RELIANCE IL as operated from each vault.
Individual light fixtures can be grouped in lighting segments spanning one or more series circuits, for example an interleaved
stop bar. In turn, the NCU provides alarm status for percentage and adjacent lamp failure within those defined lighting
segments per requirements for low visibility operations. Airfield lighting and RELIANCE IL component status are constantly
monitored and updated to the Host/Supervisor system upon occurrence.
UM-0197, Rev. 1.0, 2019/11/19
19
Copyright
©
ADB Safegate, All Rights Reserved
Summary of Contents for RELIANCE IQ L-852G(L)
Page 2: ......
Page 12: ...RELIANCE Inset Light Safety 6 Copyright ADB Safegate All Rights Reserved ...
Page 14: ...RELIANCE Inset Light About this Manual 8 Copyright ADB Safegate All Rights Reserved ...
Page 20: ...RELIANCE Inset Light Introduction 14 Copyright ADB Safegate All Rights Reserved ...
Page 50: ...RELIANCE Inset Light Spare parts 44 Copyright ADB Safegate All Rights Reserved ...
Page 51: ...UM 0197 Rev 1 0 2019 11 19 45 Copyright ADB Safegate All Rights Reserved ...
Page 52: ......