9.4.5 Output terminals
The table shows an example of functions you can configure to the output connector P1. Each signal must have its own wire. In
addition, each board must have a separate wire for a common earthing. The functions have two custom contacts, custom 1
and custom 2. You can switch the custom contacts on or off.PCB drawings and settings
Table 46: Functions for connector P1
Function
Condition
Custom 1
Custom 2
Description
REILS DOWN
ON/OFF
ON/OFF
If there is a misfire on 1 of the REIL FCUs and the
other one is switched OFF automatically, then this
terminal is activated.
Misfire on one flasher head
Fugitive
ON/OFF
ON/OFF
The terminal contacts are activated when the
misfire(s) occur(s) and are released at the next
correct flash.
Misfire on at least two
flashers heads
Fugitive
ON/OFF
ON/OFF
Misfire on two consecutive
flasher heads
Fugitive
ON/OFF
ON/OFF
Misfire on one flasher head
Latched
ON/OFF
ON/OFF
The terminal contacts are activated when the error
occurs. They remain active until the Reset Misfire
contact is activated.
Misfire on at least two
flashers heads
Latched
ON/OFF
ON/OFF
Misfire on two consecutive
flashers heads
Latched
ON/OFF
ON/OFF
Misfire limit reached
Latched
ON/OFF
ON/OFF
This terminal is activated if the number of misfires
exceeds the limit on at least one equipment. To
clear the condition, activate the reset misfire
function.
Flasher head life limit reached
Latched
ON/OFF
ON/OFF
This terminal is activated if the number of flashes
exceeds the lamp life time on at least one
equipment. The condition is cleared by activating
the reset misfire function.
Over temperature
ON/OFF
ON/OFF
When the inside temperature of an equipment or
the LMC exceeds the programmed maximum
temperature, this terminal goes active. As soon as
the temperature drops under the limit on all the
devices, the terminal goes inactive again.
Communication problems on
local bus
ON/OFF
ON/OFF
If the LMC cannot contact one of the equipments
this terminal is activated. As soon as the condition
is repaired and the equipment is back on line, the
terminal goes inactive
Security (DOOR open + MOV
blown)
ON/OFF
ON/OFF
The security parameters check for defects in the
protection of the Control units (MOV) or intrusion
(DOOR open). As soon as the condition is repaired
or the door closes, the terminal goes inactive again.
Security (DOOR
open)
ON/OFF
ON/OFF
Security (MOV
blown)
ON/OFF
ON/OFF
Free
ON/OFF
ON/OFF
This terminal is not in use.
Flasher
RUNNING
ON/OFF
ON/OFF
Contact is closed when the flasher system received
a valid step + mode command.
REILS RUNNING
ON/OFF
ON/OFF
You can switch the REILS ON or
OFF onto custom contact 1 or 2
Flashing System Maintenance
PCB drawings and settings
86
Copyright
©
ADB Safegate, All Rights Reserved
Summary of Contents for FCU-1-in-1
Page 2: ......
Page 8: ...Flashing System Maintenance TABLE OF CONTENTS viii Copyright ADB Safegate All Rights Reserved ...
Page 18: ...Flashing System Maintenance Safety 8 Copyright ADB Safegate All Rights Reserved ...
Page 28: ...Flashing System Maintenance Introduction 18 Copyright ADB Safegate All Rights Reserved ...
Page 42: ...Flashing System Maintenance Commissioning 32 Copyright ADB Safegate All Rights Reserved ...
Page 64: ...Flashing System Maintenance Maintenance 54 Copyright ADB Safegate All Rights Reserved ...
Page 106: ...Flashing System Maintenance Technical data 96 Copyright ADB Safegate All Rights Reserved ...
Page 110: ......