Refer to Figure.
Figure 8: Converter 1
Figure 9: Converter 2
Figures 1 and 2
3. Remove the fuse resistors by pulling away from the converter.
a. For converters with 1 connector, always replace both fuse resistors at the same time.
b. For converters with 2 connectors, always replace both fuse resistors related to the A/B channel that needs to be reset.
Make sure you replace all 4 fuse resistors, if both A and B channel needs a reset.
4. Dispose the old fuse resistor.
5. Place the legs of the new fuse resistors in the sockets.
6. Assemble the light fixture and perform a functional test.
5.3.11 Check the Light Fixture for Water-tightness
Tools to be used:
•
Flat head screwdriver
Execute the following procedure to test for leaks:
1. Remove the Pressure-relief Screw.
Refer to the image below.
UM-5055, Rev. 1.0.9, 2022/04/29