background image

 

 

 

DM-8 

DIGITAL MESSAGING UNIT 

Item ref: 953.053UK 

User Manual 

 

 

 

 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Version 3.1 

 

 

Caution: Please read this manual carefully before operating 

Damage caused by misuse is not covered by the warranty 

Summary of Contents for DM-8

Page 1: ...DM 8 DIGITAL MESSAGING UNIT Item ref 953 053UK User Manual Version 3 1 Caution Please read this manual carefully before operating Damage caused by misuse is not covered by the warranty ...

Page 2: ... ingress or other damage consult qualified service personnel 12 Do not place in damp areas or near liquids or moisture Do not spill liquids on the housing 13 Please pay attention to warning symbols during transit and placement 14 Terminals marked with the symbol are HAZARDOUS LIVE and should only be connected by qualified personnel 15 Ensure that the apparatus is connected to a mains socket with a...

Page 3: ... stored into a folder called MESSA which itself needs to be in the root folder of the SD card for the DM 8 to recognize them The message schedule must be stored on the SD card as a text file named as schedule txt which can be created using the free DM8_Schedule_Editor exe application This application is downloadable from http www avsl com assets downloads 953053UK_software zip and runs without ins...

Page 4: ...ng in the hour and minutes fields and entering the values directly or select from the drop down arrow to the right of each field Next click on the days of the week that this event will occur on click on ALL to fill in every day quickly if preferred Finally select the message that will be triggered on these days at the selected time from 001 to 099 When the time days and message are set click on OK...

Page 5: ...browsing to the file The format of the schedule txt document is Time Days Message all separated by commas only an example is shown opposite The Time format is 4 digit 24 hour midnight 00 00 The Days are abbreviated to the first 3 letters Monday Mon The Message is the file name without mp3 message 1 M001 If preferred the schedule file can be written from scratch without the editor software by using...

Page 6: ...ls are turned down on connected PA equipment and switch on power to the DM 8 11 The display will light to confirm power is on Turn up the OUTPUT 8 and check the MIC LINE input 2 by pressing the PAGE button to on 3 so that the indicator is lit and then speaking into the mic or playing audio whilst turning up the MIC LINE level control 1 NOTE The MIC LINE input has the highest priority and will temp...

Page 7: ...display and the output indicator 10 will show the level at the output Pressing the PAGE button 3 will stop any message playback this will activate the MIC LINE input pressing again will deactivate it If any message button is pressed whilst a message is already playing it will override the current message The CLOCK SET button 5 is also a REPEAT button Pressing this briefly before or during playback...

Page 8: ...recaution Page Rec Mic Clock Set Schedule Message 1 8 Output Power on off Specifications Power supply 100 240Vac 50 60Hz or 24Vdc Fuse T1AL 250V Inputs XLR or terminal bal unbal mic line and BGM line input RCA Audio source Internal SD card player Time setting 99 programmable schedules 24 hour day s setting Outputs Mono balanced terminal or unbalanced RCA Mic Line channel controls Mic Line level Ph...

Reviews: