E-5
Technical Specifications
Advanced SCSI features
Full backward SCSI compatibility
70 simultaneous commands and
Command Queuing supported
Reserve/Release (multihost ready, up
to 15 initiators with single controller)
Ultra160 SCSI for data transfer up to
160 MB/sec
Ultra160 SCSI connection for up to 15
devices per channel (14 in active-active
mode)
Domain validation and CRC data
protection with Ultra160
Configuration and
management
Disk Array Administrator or RS-232
serial interface to ANSI terminal or
terminal emulator
Performance statistics monitoring;
event logging, rebuild, and verify
utilities
SAF-TE and SMART environmental
monitoring support
AdminiStor support
Board form factor
4.25 in x 9.0 in PCB outline (10.80 cm x
22.86 cm)
1.1 in (2.79 cm) total height with
unbuffered DIMM,
1.2 in (3.05cm) with registered DIMM
Backplane connector
376 I/O pin AMP Z-Pack HM series
Power requirements
+5.0Vdc, 6.0A typical, 8.0A max, ±5%
input tolerance
+12.0Vdc, 0.2A max (normal
operation), 0.6A max (battery
charging), ±10% input tolerance
Battery backup
3-cell NiMH Battery Pack, with
integrated thermistor and overcurrent
fuse.
Temperature
Normal
Degraded
Non-Operating
+5
o
C to +45
o
C
0
o
C to +5
o
C and +45
o
C to +50
o
C
–40
o
C to +100
o
C
Humidity
Operating
Non-Operating
10% to 85% noncondensing
5% to 90% noncondensing
Air flow
10.0 cubic-ft/min. (CFM)
DuraStor IUG - Online.book Page 5 Friday, July 19, 2002 3:06 PM