background image

Instruction Manual

SAVE THIS MANUAL FOR FUTURE REFERENCE.

Questions?

 Contact Customer Support at 

(877) 221-1252 or visit www.

AcuRite

.com.

CONTENTS

Unpacking Instructions ........... 2

Package Contents .................. 2

Product Registration ............... 2

Features & Benefits: Sensor ..... 2

Features & Benefits: Display .... 3

Setup .................................... 5

Sensor Setup ......................... 5

Display Setup ........................ 6

Intelli-Time

®

 Clock .................. 7

Set the Time, Date & Units ...... 7

Backlight Settings ................... 7 

Placement Guidelines ............. 8

Using the Weather Station ...... 9

Troubleshooting ....................10

Care & Maintenance .............12

Calibration ...........................12

Replace Intelli-Time

®

 battery ..13

Specifications ........................14

FCC Information ...................14

Customer Support .................15

Warranty..............................15

Weather Station

model 02038 / 02041

Summary of Contents for 02038

Page 1: ...on 2 Features Benefits Sensor 2 Features Benefits Display 3 Setup 5 Sensor Setup 5 Display Setup 6 Intelli Time Clock 7 Set the Time Date Units 7 Backlight Settings 7 Placement Guidelines 8 Using the Weather Station 9 Troubleshooting 10 Care Maintenance 12 Calibration 12 Replace Intelli Time battery 13 Specifications 14 FCC Information 14 Customer Support 15 Warranty 15 Weather Station model 02038...

Page 2: ...splay unit 2 Outdoor sensor 3 Power adapter 4 Instruction Manual PRODUCT REGISTRATION Register online to receive 1 year warranty protection www AcuRite com IMPORTANT PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE Register a Product Features Benefits 4 3 2 1 5 OUTDOOR SENSOR 1 Integrated Hanger For easy placement 2 Wireless Signal Indicator Flashes when data is being sent to the display uni...

Page 3: ...rated 8 Moon Phase 9 Barometric Pressure Arrow icon indicates the direction the pressure is trending 10 Low High Humidity Records Lowest and highest indoor humidity recorded since midnight 11 Humidity Level Indicator Indicates a high low or ideal indoor humidity level 12 Current Indoor Humidity Arrow icon indicates the direction the humidity is trending 13 Low High Temperature Records Lowest and h...

Page 4: ... For setup preferences 3 Button For setup preferences 4 Button For setup preferences 5 Battery Compartment 6 Reset Button Full reset to factory defaults 7 Battery Compartment Cover 8 Plug in for Power Adapter 9 A B C Switch ID code that must match sensor s A B C switch to ensure units synchronize 10 Integrated Hang Hole For easy wall mounting ...

Page 5: ...batteries are not recommended The sensor requires lithium batteries in low temperature conditions Cold temperatures can cause alkaline batteries to function improperly Use lithium batteries in the sensor for temperatures below 4ºF 20ºC 1 Slide off the battery compartment cover Take note of the A B C switch setting inside the battery compartment for display unit setup 2 Insert 2 x AA batteries into...

Page 6: ...rgeable batteries DO NOT short circuit the supply terminals Display Unit Setup Set the A B C Switch Locate the A B C switch inside the battery compartment Set the A B C switch to A B or C You must select the same letter choices for both the display unit and the sensor in order for the units to synchronize Install or Replace Backup Batteries optional 1 Remove the battery compartment cover 2 Insert ...

Page 7: ... YEAR TEMPERATURE UNITS ºF or ºC PRESSURE UNITS inHg or hPa If you live in an area that observes DST DST should be set to ON even if it is not currently Daylight Saving Time You will automatically exit SET MODE if no buttons are pressed for 10 seconds Enter setup mode at any time by pressing the button Display Backlight Settings This weather station s color display features three different lightin...

Page 8: ...e a well covered tree branch The best location is 4 to 8 feet above the ground with permanent shade and plenty of fresh air to circulate around the sensor Important Placement Guidelines To ensure accurate temperature measurement place units out of direct sunlight and away from any heat sources or vents Display unit and outdoor sensor must be within 330 ft 100 m of each other To maximize wireless r...

Page 9: ...on RAIN SNOW MIX LIKELY Lightning Stormy windy SNOW LIKELY LIGHT RAIN LIKELY PARTLY CLOUDY SUNNY CLOUDY View the complete list of icons at www AcuRite com acurite icons Barometric Pressure Subtle variations in barometric pressure greatly affect the weather This weather station displays the current pressure with an arrow icon to indicate the direction the pressure is trending FALLING STEADY or RISI...

Page 10: ...d or the outdoor sensor The units must be within 330 ft 100 m of each other Make sure both units are placed at least 3 feet 9m away from electronics that may interfere with the wireless communication such as TVs microwaves computers etc Use standard alkaline batteries or lithium batteries in sensor when temperature is below 4ºF 20ºC Do not use heavy duty or rechargeable batteries NOTE It may take ...

Page 11: ...Mode calibrates for a total of 33 days Inaccurate temperature or humidity Make sure both the display unit and sensor are placed out of direct sunlight and away from any heat sources or vents see page 8 Make sure both units are positioned away from moisture sources see page 8 The unit lost power or batteries were changed and the time is not correct The Intelli Time battery needs to be replaced see ...

Page 12: ...just the currently selected flashing item press and release the or buttons to calibrate the data value higher or lower from the actual reading 3 To save your adjustments press and release the button to adjust the next preference The icon will remain illuminated next to calibrated values The preference set order is as follows OUTDOOR TEMPERATURE OUTDOOR HUMIDITY INDOOR TEMPERATURE INDOOR HUMIDITY B...

Page 13: ... has a shelf life of several years To replace the Intelli Time battery 1 Locate the coin cell battery compartment door on the back of the display unit Unscrew and remove the compartment cover 2 Insert 1 x CR2032 coin cell battery into the battery compartment as shown Install battery with positive terminal facing OUT 3 Screw in the battery cover CR2032 3V ...

Page 14: ... a residential installation This equip ment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which ...

Page 15: ...ies are hereby expressly disclaimed including without limitation the implied warranty of merchantability and the implied warranty of fitness for a particular purpose Chaney expressly disclaims all liability for special consequential or incidental damages whether arising in tort or by contract from any breach of this warranty Some states do not allow the exclusion or limitation of incidental or con...

Page 16: ...s AcuRite uses patented technology Visit www AcuRite com patents for details Printed in China 02041 INST 030714 It s more than accurate it s AcuRite offers an extensive assortment of precision instruments designed to provide you with information you can depend on to Plan your day with confidence www AcuRite com Weather Stations Temperature Humidity Weather Alert Radio Kitchen Thermometers Timers C...

Reviews: