Rev. 1
HEXAPAD 10 BC USB
8.9.3 Read TID memory bank and EPC tag id
With the HEXAPAD reader it is possible to read any memory bank of the EPC gen2 tag, (reserved,
epc, tid and user), just configure by
the tagop
command in which database is desired to read along
with the initial position and the size of the data (in word) that you want to read.
The syntax of the
tagop
command is explained in detail in
8.3.14 tagop - Tag read operation
. Examples:
A. Read the entire TID bank of the tag plus the EPC id in hexa:
tagop
tid:0:0<CR>
epcdecode none<CR>
Example of reading two tags with different sizes from the TID bank:
B. Read from the TID bank 4 words skipping the first 2 words and decoding the EPC id by the
ASCII table:
tagop tid:2:4<CR>
epcdecode ascii<CR>
Example of reading two tags:
In addition to TID banking, RESERVED, USER, and EPC banks can also be read in conjunction with the
EPC tag id.
NOTE:
More
details of commands in
8.3 Configuration commands
.
For reserved bank, if the tag has a recorded access password other than
NOTE:
0x00000000, the tag password must be configured on the reader by the
gen2accesspassword
.
NOTE:
The count unit in the EPC Gen2 standard is word, which is equivalent to 2 bytes or 16 bits.
Summary of Contents for HEXAPAD 10
Page 5: ...Rev 1 HEXAPAD 10 BC USB BLANK...
Page 14: ...Rev 1 HEXAPAD 10 BC USB Part 1 Overview and installation Equipment Overview Installation...
Page 15: ...Rev 1 HEXAPAD 10 BC USB 6 Equipment overview 6 1 Hardware HEXAPAD...
Page 17: ...Rev 1 HEXAPAD 10 BC USB 6 2 1 Barcode reading angulation Field Vision Field Vision...
Page 19: ...Rev 1 HEXAPAD 10 BC USB 2 Big carcode Barcode placement...
Page 23: ...Rev 1 HEXAPAD 10 BC USB 6 2 1 3 VSWR integrated antenna 6 2 1 4 Gain Far Field...
Page 27: ...Rev 1 HEXAPAD 10 BC USB 7 1 1 1 2 Step 2 Load the driver 1 Right click go to Update Driver...
Page 80: ...Rev 1 HEXAPAD 10 BC USB...