458
ACU-RITE Technical Manual MILLPWR
G2
6.10 Operating Times and System Times
6.10.1 Measuring Operating Times
The control can measure up to 11 operating times (operating hours counter)
and store them in a file:
The time is measured in seconds and is updated every minute during the run
time. When the control is switched off, no more than one minute is lost.
The MILLPWR
G2
starts and stops the NC operating hours counter (
Control
on,
Machine on
and
Program run
).
PLC operating hours counters 1 to 8:
Start with Module 9190.
Stop with Module 9191.
All operating times are saved during a system backup. .
Settings in the configuration editor:
System
CfgPlcOperTimes
displayPlcTimes
resetPlcTimes
resetNcTimes
textNumber
Operating time
Meaning
TNCTIME
Control on
MACHINETIME
Machine on (NC operating time)
PROGTIME
Program run (NC operating time)
PLCTIME0 to PLCTIME7
Freely definable PLC operating time
Summary of Contents for MILLPWR G2
Page 1: ...Technical Manual ACU RITE MILLPWRG2 ...
Page 2: ......
Page 14: ...14 ACU RITE Technical Manual MILLPWRG2 ...
Page 40: ...40 ACU RITE Technical Manual MILLPWRG2 ...
Page 58: ...58 ACU RITE Technical Manual MILLPWRG2 3 10 3 USB Hub ...
Page 60: ...60 ACU RITE Technical Manual MILLPWRG2 TS 220 Adapter cable for TS 120 TS 220 ...
Page 61: ...3 10 Dimensions 61 SE 640 transmitter receiver unit ...
Page 62: ...62 ACU RITE Technical Manual MILLPWRG2 SE 540 transmitter receiver unit ...
Page 63: ...3 10 Dimensions 63 TS 440 TS 640 ...
Page 64: ...64 ACU RITE Technical Manual MILLPWRG2 ...
Page 392: ...392 ACU RITE Technical Manual MILLPWRG2 ...
Page 545: ......