6.8 Override
449
6.8 Override
6.8.1 Override Devices
The control supports the following override devices:
Up to two potentiometers
Group of keys (You can use two machine operating keys for setting the over-
ride value.)
The input values of the override devices (potentiometer setting or key input)
are evaluated as follows:
DISCRETE: The control converts the input values into a maximum of 64 dis-
crete override values.
LINEAR: The control interpolates the input values linearly between the min-
imum and maximum override value.
CURVE: The control uses a curve to convert the lower input values into over-
ride values. In this way you can achieve a finer resolution of the lower over-
ride values. Higher input values are again interpolated linearly.
Define the override devices as follows:
Define the override device in MP_source.
In MP_mode, define the evaluation of the override input.
In MP_values, define the discrete override values or the interpolation points
of the curve.
Settings in the configuration editor:
System
PLC
CfgPlcOverrideDev
Key for override device
source
mode
values
Summary of Contents for MILLPWR G2
Page 1: ...Technical Manual ACU RITE MILLPWRG2 ...
Page 2: ......
Page 14: ...14 ACU RITE Technical Manual MILLPWRG2 ...
Page 40: ...40 ACU RITE Technical Manual MILLPWRG2 ...
Page 58: ...58 ACU RITE Technical Manual MILLPWRG2 3 10 3 USB Hub ...
Page 60: ...60 ACU RITE Technical Manual MILLPWRG2 TS 220 Adapter cable for TS 120 TS 220 ...
Page 61: ...3 10 Dimensions 61 SE 640 transmitter receiver unit ...
Page 62: ...62 ACU RITE Technical Manual MILLPWRG2 SE 540 transmitter receiver unit ...
Page 63: ...3 10 Dimensions 63 TS 440 TS 640 ...
Page 64: ...64 ACU RITE Technical Manual MILLPWRG2 ...
Page 392: ...392 ACU RITE Technical Manual MILLPWRG2 ...
Page 545: ......