Lampe UV
en march
e lorsque
le voyant e
st allumé.
UV Lamp i
n operatio
n when lit
.
HVAC EN
VIRONM
ENTAL CO
NDITION
ING SYST
EM
SYSTÈM
E DE CON
DITIONN
EMENT D
’AIR CVC
READ MANUAL CAREFULLY FOR PROPER USE AND OPTIMAL OPERATION.
Page 1: ...LampeUVenmarchelorsquelevoyantestallum UVLampinoperationwhenlit HVACENVIRONMENTALCONDITIONINGSYSTEM SYST MEDECONDITIONNEMENTD AIRCVC READ MANUAL CAREFULLY FOR PROPER USE AND OPTIMAL OPERATION...
Page 2: ...nd air disinfection Please read and follow all service procedures outlined in this manual before installing or performing maintenance STORAGE AND DISPOSAL Do not dispose of this product as household w...
Page 3: ...ocation for Protective Earth Line CAUTION Wiring and installation of this unit must be done by a licensed HVAC contractor or electrician failure to do so will void warranty of the product When the uni...
Page 4: ...vice DIRECTIONS FOR USE Unit should be installed after the air handler in the HVAC system by a licensed HVAC contractor or electrician Please see owner s manual for detailed instructions on using hand...
Page 5: ...UV Bulb INSTALLATION HARDWARE SUPPLIED 8 8 75 1 4 Self tapping screws Item US7067 2 Thumb screws Item 36 00213 4 Thumb nuts Item 36 00214 4 6 32 x 2 inch Threaded bolts Item US70680 4 6 32 Toggle bol...
Page 6: ...at operates at nominal voltages between 100 and 240 VAC 50 60 Hz CAUTION To Reduce the Risk of Electric Shock DO NOT use in wet or damp locations This equipment emits UV C radiation DO NOT locate equi...
Page 7: ...t into HVAC system must be done by a licensed HVAC installer or electrical contractor only When the unit is installed in a roof mounted HVAC system the unit must be protected from elements Unit requir...
Page 8: ...plate using 8 8 self tapping screws 8 Insert unit into opening Be sure the air will pass though the ActivePure Cell honeycomb matrix 9 Secure the unit to the mounting plate with 4 thumb nuts 10 Plug u...
Page 9: ...the AC unit or power box Hard wiring unit into HVAC system should be done by a licensed HVAC installer or qualified electrical contractor only CAUTION WIRING THE UNIT Your ActivePure Induct Guardian...
Page 10: ...e new ActivePure Cell into the base unit Be sure Air Flow Honeycomb Cell direction is correct WARNING UV Light in operation disconnect unit from power cord before servicing failure to follow warnings...
Page 11: ...sque levoyant est allum UV Lamp in operation when lit HVACENVIRONMENTALCONDITIONINGSYSTEM SYST MEDECONDITIONNEMENTD AIRCVC 1 Disconnect unplug power cord from unit Power Cord Never attempt to check op...
Page 12: ...ect wiring A press each tab on the ballast and insert wire B Release tab and gently pull wire to ensure it is properly locked into place LED LED RED RED BLUE BLUE BLACK WHITE GREEN A B UPPER 6 termina...
Page 13: ...email customerservice ActivePure com REPLACEMENT PARTS SERVICE Limited Five 5 Year Warranty To register your ActivePure Induct Guardian unit visit www activepure com warranty To view full details on w...
Page 14: ...can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Inc...
Page 15: ...15...
Page 16: ...Customer Service 1 800 572 1446 or email at customerservice ActivePure com www activepure com ActivePure Manufacturing LLC 1300 Valley Drive Bristol VA 24201 800 572 1446 Assembled in U S A ActivePure...
Page 17: ...quelevoyantestallum UVLampinoperationwhenlit HVACENVIRONMENTALCONDITIONINGSYSTEM SYST MEDECONDITIONNEMENTD AIRCVC LIRE ATTENTIVEMENT LE MANUEL AFIN D UTILISER CORRECTEMENT L APPAREIL ET D ASSURER SON...
Page 18: ...d sinfection des surfaces et de l air 24 h 24 et 7 j 7 Veuillez lire et suivre toutes les proc dures d entretien d crites dans le pr sent manuel avant de l installer ou de le r parer STOCKAGE ET MISE...
Page 19: ...mise la terre ATTENTION Le branchement et l installation de cet appareil doivent tre effectu s par un fournisseur ou un lectricien agr en CVC sinon la garantie du produit sera annul e Si l appareil es...
Page 20: ...tall sur l unit de traitement de l air dans le syst me CVC par un fournisseur ou lectricien agr en CVC Veuillez consulter le manuel d utilisation pour des instructions d taill es sur l utilisation la...
Page 21: ...D INSTALLATION FOURNI 8 Vis autotaraudeuses po 0 75 8 Pi ce US7067 2 Vis de serrage Pi ce 36 00213 4 crous ailettes Pi ce 36 00214 4 Boutons filet s 32 x 2 po 6 Pi ce US70680 4 32 Boulon ailettes pou...
Page 22: ...et 240 VCA 50 60 Hz ATTENTION Afin de r duire le risque de d charge lectrique NE PAS utiliser dans des lieux mouill s ou humides Cet appareil met un rayonnement UVC Ne pas placer l appareil dans un li...
Page 23: ...un installateur ou un lectricien CVC agr uniquement Si l appareil est install dans un syst me CVC fix sur un toit il doit tre prot g des l ments L appareil doit tre branch une source d alimentation e...
Page 24: ...l appareil dans l ouverture Assurez vous que l air passera travers la matrice alv olaire de la cellule ActivePure 9 Fixez l appareil la plaque de fixation avec 4 crous 10 Branchez l unit une prise de...
Page 25: ...nt l appareil la surface m tallique du climatiseur ou du bloc d alimentation Le c blage de l appareil dans un syst me CVC doit tre effectu par un installateur CVC agr ou un lectricien qualifi uniqueme...
Page 26: ...lule ActivePure dans la base de l appareil Assurez vous que l orientation du d bit d air de la cellule alv olaire est correcte MISE EN GARDE Lampe UV en marche d brancher l appareil du cordon lectriqu...
Page 27: ...en lit HVACENVIRONMENTALCONDITIONINGSYSTEM SYST MEDECONDITIONNEMENTD AIRCVC 1 D connectez d branchez le cordon lectrique de l appareil Cordon lectrique N essayez jamais de v rifier le fonctionnement d...
Page 28: ...ue languette et ins rez le fil B Tirez doucement sur les fils pour vous assurer qu ils sont correctement maintenus en place LED LED RED RED BLUE BLUE BLACK WHITE GREEN A B HAUT 6 terminaux Fil noir LE...
Page 29: ...ECHANGE ET SERVICE Garantie limit e de 5 ans Pour enregistrer votre ActivePure Induct Guardian rendez vous sur www activepure com warranty Pour connaitre tous les d tails de la couverture de la garant...
Page 30: ...vision ce qui peut tre d termin en allumant et en teignant l appareil l utilisateur est encourag tenter de corriger l interf rence par une ou plusieurs des mesures suivantes R orienter ou d placer l a...
Page 31: ...31...
Page 32: ...contacter le service la client le 1 800 572 1446 ou crivez customerservice ActivePure com www activepure com ActivePure Manufacturing LLC 1300 Valley Drive Bristol VA 24201 1 800 572 1446 Fabriqu aux...