background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Manual Ray-On 
PoE 

 

For column models  
B70 PoE, R70 PoE, R110 PoE

 

Summary of Contents for Ray-On B70 PoE

Page 1: ...Manual Ray On PoE For column models B70 PoE R70 PoE R110 PoE ...

Page 2: ...User Manual Ray On PoE series 2 sur 22 DOP1066_A ...

Page 3: ... 1 PoE technology 8 3 2 PoE network verification 8 3 3 Choice and connection of the PSE 8 4 Wiring 9 4 1 Setting 10 5 Technical drawings 15 5 1 R70 PoE and R110 PoE 15 Fixation dimensions 15 5 2 B70 PoE 16 Fixation dimensions 16 6 Specifications 17 7 Acoustical data 18 a R70 PoE acoustical data 18 b R110 PoE acoustical data 19 c B70 PoE acoustical data 20 8 Declaration of conformity 21 ...

Page 4: ...n to keep the cable in good condition o Do not overload the cable placing heavy or sharp objects on the cable o Do not bend the cable beyond the radius of curvature indicated by its manufacturer o Do not staple the cable o Keep the cable away from a heat source If the following events occur immediately disconnect the power source Finding of a damaged cable Unusual odor or release of smoke Introduc...

Page 5: ...dors escalators shopping alleys shopping malls railway platforms B70 will also ensure the sound reinforcement of spaces with limited coverage areas such as video conferencing equipment huddle rooms small spaces in museums The arc position of the drivers allows a perfect directivity control in the spatially and in the frequency domain This directivity control allows to limit the sound disturbance i...

Page 6: ...ect SPL On the contrary installing the column lower will increase SPL but decreases its range Figure 2 5dB range m according to mounting height from floor to bottom of column in m for the direct field at mid frequencies 300Hz 3kHz Mounting height Minimal Nominal Maximal Ray On R70 PoE Standing audience 1 55m 2m 2 50m Seated audience 1 15m 1 60m 2 10m Ray On R110 PoE Standing audience 1 55m 2 20m 2...

Page 7: ...a in transverse direction Figure 5 Width of the covered area and advised distance between loudspeakers according the mounting height 0 1 2 3 4 5 6 7 8 9 3 4 5 6 7 8 Beam width in the liddle of the covered area m Distance between B70 and the middle of the covered area m Beam width for different mounting height of B70 B70 3m above the listening plan B70 4m above the listening plan B70 5m above the l...

Page 8: ...he following points should be checked In order to be compatible with PoE technology the network to which the speakers are connected must be made with cables and connectors of type CAT5 or higher CAT6 CAT7 The loss of power being linked to the length of the cables the network to which the speakers are connected must have the shortest cable lengths possible and compatible with the Ethernet standard ...

Page 9: ... it is possible to position a PoE injector between the switch and the cable connected to the enclosure This device allows power to be sent over the network link without changing the topology or routing properties of the existing network Ray On PoE speakers must be connected to PoE type injectors IEEE802 3at 4 Wiring Figure 6 Wiring Ray On PoE columns POWER SUPPLY ...

Page 10: ...perate The commissioning and configuration of Ray On PoE requires connecting a computer equipped with DANTE CONTROLLER software to the network This software can be downloaded for free from the Audinate web site www audinate com Before putting Ray On PoE into service make sure that the network configuration is similar to that shown in the diagram below Figure 7 Configure Ray On PoE columns using th...

Page 11: ... Connect the speakers one by one on the network After each connection Check that the speaker is correctly connected to the network If the speaker is correctly connected to the network the configuration of the LEDs located at the RJ45 connector on the speaker is as follows ...

Page 12: ...eries 12 sur 22 DOP1066_A Then access the Device View in DANTE CONTROLLER Menu Device Device View The Receive tab allows you to view the device connected to the speaker the connection status as well as the presence of a signal ...

Page 13: ...User Manual Ray On PoE series 13 sur 22 DOP1066_A After having refreshed the equipment connected in DANTE CONTROLLER F5 key the speaker must appear by its address at the Status tab ...

Page 14: ...In the Network Config tab it is recommended to remain in auto IP except installation requiring fixed IP Speaker setting The DSP processor built into the Ray On PoE enclosure incorporates EQ settings for optimal sound quality Once the rooting is done in DANTE CONTROLLER no other action is necessary to operate Ray On PoE If room equalization is reguired this will be done on the DANTE matrix or on th...

Page 15: ...s are vertically mounted usually on a wall using the supplied wall mounting system See also figure 9 for the technical drawings of the wall mounting system It is important to ensure verticality when mounting Ray On PoE columns Fixation dimensions Figure 8 Mechanical drawings Figure 9 General and back view of fixation R70 PoE R110 PoE ...

Page 16: ...E is horizontally mounted usually on a wall or hanged from the ceiling using the supplied mounting systems See also figure 11 for the technical drawings of the mountings system Fixation dimensions Figure 10 Mechanical drawings Figure 11 General and back view of fixation ...

Page 17: ...W Max SPL 88dB at 5m 102dB at 1m Power supply RJ45 Tilting angle of audience area 0 5 Frequency bandwidth 10dB 120Hz 18kHz Opening angle at 6dB 100 70 Network 1xRJ45 connector DanteTM Mechanical data Max operating ambient temperature 55 C Net weight 7 0kg Shipping weight 7 5kg Height 706mm Width 128mm Depth 117mm Standard colors white RAL 9016 black RAL 9005 Acoustical data Electrical data Range 3...

Page 18: ...ominal position and using nominal filtering parameters a R70 PoE acoustical data Figure 12 R70 PoE directivity sound level for the voice octaves 500Hz 1kHz 2kHz Left horizontal Right vertical Figure 13 R70 PoE Frequency response 1W at reference point left Impedance right 0dB corresponds to the efficiency dB 1W the reference point ...

Page 19: ...ustical data Figure 14 R110 PoE directivity sound level for the voice octaves 500Hz 1kHz 2kHz Left horizontal Right vertical Figure 15 R110 PoE Frequency response 1W at reference point left Impedance right 0dB corresponds to the efficiency dB 1W the reference point ...

Page 20: ...User Manual Ray On PoE series 20 sur 22 DOP1066_A c B70 PoE acoustical data Figure 16 Horizontal and vertical polar curves of B70 PoE Figure 17 Frequency response left Impedance right ...

Page 21: ...cel Paul 44800 St Herblain France Declares under our sole responsibility that the following products B70 PoE R70 PoE R110 PoE Comply with the council directive 2004 108 CE Assessment of compliance is based on the following standards EN50081 1 EN61000 EN60065 Established on the 2nd of January 2020 by Régis CAZIN CEO ...

Page 22: ...User Manual Ray On PoE series 22 sur 22 DOP1066_A www activeaudio fr info activeaudio fr Tel 33 0 2 40 46 66 64 ...

Reviews: