PRODUCT OPERATION
TGU-R ACCESS shall not be used in environment not compliant to its specification.
User shall check that installation and operating range conditions are inside this user manual and product specification
especially on:
Power supply input range
Operating temperature range
Storage conditions
VI.1
T
RANSPORTATION AND STORAGE
:
TGU-R ACCESS transportation must be done only using the original packaging.
Before TGU-R ACCESS installation and during transportation, ACTIA recommend to store the product in its original
packaging, in a suitable indoor location with following conditions, to optimize internal battery pack option, RTC coin
cell and other components life duration:
Unit
min
Typ
Max
Conditions
Optimal storage
temperature
before installation and
during transportation
°C
10
20
30
To prevent decrease of battery pack
and coin cell and other components
life duration
Relative Humidity storage
%
40
-
75
Storage duration @above
optimal storage
temperature range
before installation and
during transportation
Year
1
To prevent deep discharged battery
pack (for product variants without
battery pack option, the duration is
limited by RTC coin cell life time : 10
years max )
Also applicable for battery spare part
Recommended min
optional battery pack
charging level
%
30
*
To prevent deep discharge
*Note: Maximum charging level
during transportation shall be set
according to transportation rules
applicable in the countries.
VI.2
H
ANDLING
:
TGU-R ACCESS must be handled with care to avoid excessive shocks and unexpected fall down during handling,
installation or use.
VI.3
SIM
CARD
:
SIM card operating temperature range shall be chosen by customer to comply with their target application ambient
operating temperature range + 10°C to consider TGU-R internal self-heating:
Examples:
Using standard SIM card with operating temperature range = -20°C to +70°C
customer will be limited to
following TGU-R application ambient temperature range = -20°C to +60°C
Using rugged SIM card with operating temperature range = -40°C to +105°C
customer will reach full TGU-R
application ambient temperature range = -40°C to +85°C
VI.4
N
ETWORK OPERATOR
:
Network operator shall be selected by customer to comply with their target application needs:
countries coverage according to supported TGU-R frequencies (see §IV.4)
countries regulations (product shall be certified on target countries usage, see §) and some local countries
request the use of local server and SIM card
data exchange quantity
When using AT&T SIM cards, under AT&T request, customer shall provide annually TGU-R product IMEI list