www.acti.com
VMGB-
370 User’s Manual
24
Measure Face Temperature in Optical Channel
1. Go to
Configuration
→
Body Thermography
→
Body Thermography Configuration
.
2. Select the optical channel.
3. Check
Enable Face Detection
to detect human faces, and measure the temperature in the
scene.
4. Check
Display Temperature
to display the highest temperature of each detected face in live
view.
5. Check
Upload Captured Face Image
to capture and upload the face image of the target. If
face detection function is also enabled, max. temperature of the face displays on the image.
NOTE:
Refer to face capture section to set the corresponding parameters.
6. Check
Display Face Temperature Position
to show a cursor on the position of max.
temperature.
7. Select
Configuration
mode.
Targeting
refers to measure the temperatures for all the targets
in the scene, and output alarm if the target temperature is higher than the alarm threshold.
NOTE:
If temperatures of multiple targets are higher than the alarm threshold, then multiple
alarms will be triggered.
8. Set the face detection parameters.
Pupil Distance
: The pupil distance refers to the square size composed by the area
between two pupils, and it is the basic standard for a camera to identify a target. You can
enter the pupil distance value or draw pupil distance areas in live view.
Generation Speed
: It refers to the target generation speed. The higher the value is, the
easier the target can be detected.
Sensitivity
: It refers to face detection sensitivity.
Alarm When Temperature is Above
: It refers to the temperature alarm threshold. When
the target temperature is higher than the setting value, the device outputs alarm.
Pre-Alarm Temperature
: When the face temperature is higher than the set value, the
device outputs pre-alarm and upload captured face image.
9. Click
Draw Area
, and draw a face detection area in live view. You can move the rectangle or
drag the corners of rectangle to adjust the position and size.
NOTE:
You should draw the detection area within the red rectangle.
10. Click
Save
.
11. Set the arming schedule and linkage methods. For the information about arming schedule
. For the information about linkage methods, see