Set Body Thermography
Measured Body Temperature in Thermal Channel
1.
Go to
Configuration
→
Body
Thermography
→
Body Thermography Configuration
.
2.
Select thermal channel.
3. Click
Draw Area
, then click the mouse on the black body in live view and save it.
4. Set the black body parameters.
Emissivity
: Set the emissivity of black body.
NOTE:
Refer to the emissivity table for reference in the manual or online.
Distance
: The straight-line distance between the black body and the device.
Temperature
: Enter the temperature of the black body.
5. Set
Environmental Temperature Mode
.
Auto
and
Manual
are selectable. In auto mode, the
device detects environment temperature automatically. In manual mode, you should enter
environment temperature manually.
6. Set the body temperature compensation parameters if you need to detect human body
temperature instead of shell temperature.
i.
Enable body temperature compensation function.
ii.
Select the compensation type.
iii.
In auto mode, the device calculates compensation value automatically. If the detected
body temperature is still inaccuracy, you can set
Manual Calibration
value.
iv.
In manual mode, you should enter
Manual Calibration
value, and corresponding
compensation value displays in
Compensation Value
field.
7. Click
Save
.
8. Set the arming schedule and linkage methods. For the information about arming schedule
. For the information about linkage methods, see
..