Actel ARTU Series Installation And Operation Manual Download Page 5

2

3. Technical Parameters
Subject:

Power supply

AC/DC 85-265V

DC48V

Power

consumption

9W (excluding modules);

15W (including modules, up to 3 modules)

Model

ARTU100-K32

32-path DI (active/passive, optional)

ARTU100-K16

16-path DI (active/passive, optional)

ARTU100-KJ8

8-path DI (active/passive, optional); 8-path DO, output mode:
relay normally-open contact output, contact capacity:
AC 250V/3A DC 30V/3A;

Communication

485
communication

RS485
interface

2-path 485 communication; Modbus-RTU protocol;
baud-rate 1200 ~ 38400bps

Others

Dial switch

10 bits

Indicator light

20 indicator lights

Optional features:

Model

CE

1 path ethernet

TCP/IP protocol

10M/100M self-adaptive

MKA18

Switch input

18-path DI (active AC 220V)

MJ12

Switch output

12-path DO output mode: Relay normally-open
contact output

MA84

Analog input

8-path AI; 0-5V, 1-5V, 4-20mA, 0-20mA, optional

Analog output

4-path AO; 0-5V, 1-5V, 4-20mA, 0-20mA,
optional

AWT100-2G

2G

communication

terminal

AWT100-Lora

Lora

communication

terminal

AWT100-LW

LoRAWAN

communication

terminal

AWT100-NB

NB-IoT

communication

terminal

AWT100-4G

4G

communication

terminal

Other technical parameters:

Security

Working
withstand
voltage

Power-frequency withstand voltage: Shell and power supply,
switch input, switch output, analog input, analog output,
communication, AC 2kV 1min; AC 2kV 1min between power

Summary of Contents for ARTU Series

Page 1: ...426 ARTU Series of Remote Terminal Units Installation and Operation Manual V1 0 Acrel Co Ltd...

Page 2: ...reproduced or disseminated in any form otherwise all consequences shall be borne by the offender The Company reserves all legal rights The Company reserves the right to modify the product specificati...

Page 3: ...ettings 13 6 1 1 Dial code definition 13 6 1 2 Address settings 13 6 1 3 Baud rate settings 13 6 1 4 Mode settings 13 6 1 5 Format settings 13 6 2 Modbus function code description 14 6 2 1 Exception r...

Page 4: ...ion network specification Part 1 Modbus application protocol GB T 19582 2 2008 Modbus industrial automation network specification Part 2 Modbus protocol implementation guide over serial link GB T13729...

Page 5: ...ator lights Optional features Model CE 1 path ethernet TCP IP protocol 10M 100M self adaptive MKA18 Switch input 18 path DI active AC 220V MJ12 Switch output 12 path DO output mode Relay normally open...

Page 6: ...0 70 Relative humidity 95 without condensation Altitude 2500m 4 Installation and Wiring 4 1 Outline dimensions 4 2 Installation methods Guide rail and wall hanging double installation methods are used...

Page 7: ...32 33 34 35 36 38 39 37 40 40 DI9 48 39 38 47 46 45 44 43 42 41 7 17 5 2 1 N L 32DI2DO 64 61 63 62 60 59 58 57 56 55 54 53 52 51 50 49 16DI8AI2DO A1 B1 A2 B2 DI2 DI3 DI DI1 21 22 24 25 26 30 31 32 33...

Page 8: ...r lights Modules Specifications MKA18 MJ12 MA84 Indicator light description 1 POW refers to the power light 2 The number refers to the channel number the odd number refers to the red light and the eve...

Page 9: ...6 32 Active input node 12V 5 Communication Description 5 1 Full parameter information of instrument Modbus function code 03 03H 04 04H can be used to access all contents in the address table and funct...

Page 10: ...int16 R W 4 0x1452 high 255 low 255 0x1453 high 255 low 0 0x1454 0x1455 Gateway Address Uint16 R W 4 0x1454 high 192 low168 0x1455 high 0 low0 0x1456 Port Number Uint16 R W 2 Default 5000 0x2000 Main...

Page 11: ...7 Statue Uint16 R 2 0 opening 1 closing 0x5012 DI48 33 Statue Uint16 R 2 0 opening 1 closing 0x5013 DI64 49 Statue Uint16 R 2 0 opening 1 closing 0x5014 DI80 65 Statue Uint16 R 2 0 opening 1 closing 0...

Page 12: ...2 1 0 20mA 2 4 20mA 3 0 5V 4 1 5V 0x5501 AI 1High Int16 R W 2 0x5502 AI1 Low Int16 R W 2 0x5503 AI2 Style Uint16 R W 2 1 0 20mA 2 4 20mA 3 0 5V 4 1 5V 0x5504 AI2 High Int16 R W 2 0x5505 AI2 Low Int16...

Page 13: ...event record number Uint16 R 2 0xD001 Action date High byte year Low byte month Uint16 R 2 0xD002 Action time High byte day Low byte time Uint16 R 2 0xD003 Action minutes and seconds High byte minute...

Page 14: ...4 DI5 state BIT R 0 opening 1 closing 0x0005 DI6 state BIT R 0 opening 1 closing 0x0006 DI7 state BIT R 0 opening 1 closing 0x0007 DI8 state BIT R 0 opening 1 closing 0x0009 DI9 state BIT R 0 opening...

Page 15: ...0x01 0x02 0x01 0x10 0xA0 0x44 Note 0x 10 is converted to a binary number of 0001 000 that is the fifth switch is in the connected status and the rest are in the disconnected status Example 3 Read the...

Page 16: ...ings 6 1 1 Dial code definition 1 2 3 4 5 6 7 8 9 10 Address settings 1 0 0 0 0 Baud rate settings 0 0 Mode settings 0 Communication mode settings 0 0 6 1 2 Address settings Dial code 1 Dial code 2 Di...

Page 17: ...ritten 6 2 2 Status of the used Modbus 01H 02H function Reading required by the upper computer MODBUS 01H 02H function Address Function Address Data CRC check BYTE BYTE WORD WORD WORD XX XX 01H 02H XX...

Page 18: ...on Exception error code data CRC check BYTE BYTE BYTE WORD XX XX 85H XX 02H address error 03H data error XXXX CRC check value 6 2 5 Write multiple data by using Modbus 10H function Write multiple data...

Page 19: ...ing to the station number and baud rate of the module in the protocol format At this time the communication indicator light of the module flashes indicating that the module has received the command of...

Page 20: ...ax 0086 21 69158303 Web site www acrel electric com E mail ACREL008 vip 163 com Postcode 201801 Manufacturer Jiangsu Acrel Electrical Manufacturing Co LTD Address No 5 Dongmeng Road Dongmeng industria...

Reviews: