Acson international AWM10FW Installation Manual Download Page 8

1-8

SERVICE AND MAINTENANCE

Maintenance Procedures

1. Remove any dust adhering to the filter by using a vacuum cleaner or

wash in lukewarm water (below 40°C) with a neutral cleaning detergent.

2. Rinse the filter well and dry before placing it back onto the unit.

3. Do not use gasoline, volatile substances or chemicals to clean the filter.

1. Clean any dirt or dust on the grille or panel by wiping it with a soft

cloth soaked in lukewarm water (below 40°C) and a neutral detergent
solution.

2. Do not use gasoline, volatile substances or chemicals to clean the

indoor unit.

Period

At least once
every 2 weeks.

More frequently if
necessary.

At least once
every 2 weeks.

More frequently if
necessary.

Service Parts

Indoor air filter

Indoor unit

When The Unit Is Not To Be Used For An Extended Long Period Of Time

Operate the unit for 2 hours
with the following setting.

Operating mode : cool
Temperature : 30°C

Remove the power plug.
If you are using an independent
electric circuit for your unit,
cut off the circuit.
Remove the batteries in the
remote control.

If any malfunction of the air conditioner unit is noted, immediately switch off the power supply to the unit.
Check the following fault conditions and causes for some simple trouble shooting tips.

TROUBLE SHOOTING

Causes / Action

– Power failure, or the fuse needs to be replaced.

– The power plug is disconnected.

– If the fault persist after all these verifications, please contact the air

conditioner unit installer.

– The air filter is dirty.

– The doors or windows are open.

– The air suction and discharge are clogged.

– The regulated temperature is not high enough.

– Odors may be caused by cigarettes, smoke particles, perfume etc.

which might have adhered onto the coil.

– This is caused by air humidity after an extended long period of

operation.

– The set temperature is too low, increase the temperature setting and

operate the unit at high fan speed.

– Switch off unit and call dealer.

Fault

1. The air conditioner unit does not operate.

2.   The air flow is too low.

3. Discharge air flow has bad odor.

4. Condensation on the front air grille of the indoor unit.

5. Water flowing out from the air conditioner unit.

If the fault persists, please call your local dealer / serviceman.

!

 Warning

Disconnect from the main power supply before servicing the air conditioner unit.

DO NOT pull out the power cord when the power is ON. This may cause serious electrical shocks which
may result in fire hazards.

!

 Caution

Do not operate any heating apparatus too close to the air conditioner unit. This may
cause the plastic panel to melt or deform as a result of the excessive heat.

Summary of Contents for AWM10FW

Page 1: ...requirements Before using your air conditioner please read this instruction manual carefully and keep it for future reference INSTALLATION MANUAL WALL MOUNTED CHILLED WATER FAN COIL UNIT MODEL COOLIN...

Page 2: ...the fan motors Confirm that the unit has been switched OFF before installing or servicing the unit IMPORTANT DO NOT INSTALL OR USE THE AIR CONDITIONER UNIT IN A LAUNDRY ROOM Outline And Dimensions pag...

Page 3: ...the weight of the unit Otherwise it is necessary to reinforce the wall with plates beams or pillars Use the level gauge for horizontal mounting and fix it with 4 suitable screws In case the rear pipin...

Page 4: ...h is the minimum requirement Cooling unit IMPORTANT The figures shown in the table are for information purpose only They should be checked and selected to comply with the local national codes of regul...

Page 5: ...s solenoid valve filter strainer etc IR Signal Receiver When an infrared remote control operating signal has been transmitted the signal receiver on the indoor unit will make a beep sound to confirm a...

Page 6: ...ature it will directly operate under dry mode The unit will operate at LOW speed under dry mode Fan Speed And Rated Cooling Capacity The rated cooling capacity is provided at the maximum fan speed The...

Page 7: ...dorizing Black Colour Place Filter Into The Filter Frame Ionizer Filter Top Press Downward To Lock A To Open The Filter Frame Caution 1 The electrostatic air purifying and deodorizing filter should be...

Page 8: ...ons and causes for some simple trouble shooting tips TROUBLE SHOOTING Causes Action Power failure or the fuse needs to be replaced The power plug is disconnected If the fault persist after all these v...

Reviews: