1-6
LED Indicator Lights : Normal Operation And Fault Conditions For Cooling Unit
Operation / Fault Indication
Action
Cool mode
–
Heat mode
–
Fan mode
–
Dry mode
–
Room sensor missing
–
Pipe sensor missing
–
ON or OFF
ON
Blinking
Cool
Dry
Sleep
Heat
Fan
Horizontal
Cooling
Dry
AIR CONDITIONER UNIT OPERATION
Dry Mode
•
When the air humidity is high, the unit can operate in
dry mode. Press <MODE> button and choose <DRY>.
•
If the room temperature is 2°C higher than the set
temperature, the air conditioner will operate under
cooling mode until it reaches within the 2°C range of
difference compared to the set temperature before it
converts to dry mode.
•
If the room temperature is within the 2°C range of
difference compared to the set temperature, it will
directly operate under dry mode.
•
The unit will operate at LOW speed under dry mode.
Fan Speed And Rated Cooling Capacity
•
The rated cooling capacity is provided at the maximum
fan speed.
•
The cooling capacity is lower when the unit is operating
at MEDIUM and LOW fan speed.
STANDARD OPERATING CONDITIONS
Cooling Unit
Temperature
Ts ºC
Th °C
Minimum indoor
19.4
13.9
temperature
Maximum indoor
26.7
19.4
temperature
Minimum outdoor
19.4
13.9
temperature
Maximum outdoor
46
24
temperature
Ts: Dry bulb temperature.
Th: Wet bulb temperature.
Horizontal Air Flow Control
•
For more effective air circulation, you can manually
adjust the air discharge grille to the left or right.
•
During cool mode operation and dry mode operation,
do not direct the air discharge louver downwards for too
long. If operating continues in this way, condensation
may occur on the louver, thus resulting in drippings.
* Dry mode = Cool mode at low fan