ACS Fluxicont FP Manual Download Page 5

ACS-CONTROL-SYSTEM GmbH

 l Lauterbachstr. 57 l D-84307 Eggenfelden l www.acs-controlsystem.de l [email protected]

5

Safety notes

Each person that is engaged with inauguration and operation of this device, must have read and

understood this technical manual and especially the safety notes.

Installation, electrical connection, inauguration and operation of the device must be made by a 

qualified employee according to the informations in this technical manual and the relevant standards 

and rules.

The device may only be used within the permitted operation limits that are listed in this technical 

manual.

Every use besides these limits as agreed can lead to serious dangers.

The materials of the device must be chosen resp. checked for compatibility with the respective 

application requirements (contacting materials, process temperature). An unsuitable material can lead 

to damage, abnormal behavior or destruction of the device and to the resulting dangers.

The sensors may not be used as sole device for prevention of dangerous conditions in machines and 

plants.

This measuring device meets article 3 (3) of the EC directive 97/23/EC (pressure equipment device 

directive) and is designed and produced in good engineer practice.

The device meets the legal requirements of all relevant EC directives.

Using the device in a manner that does not fall within the scope of its intended use, disregarding 

this instruction, using under-qualified personnel, or making unauthorized alterations releases the 

manufacturer from liability for any resulting damage. This renders the manufacturer‘s warranty null 

and void.

Summary of Contents for Fluxicont FP

Page 1: ...1 bar to 100 bar Integrated evaluation electronic Direct voltage with PNP switch output Universal voltage with relay output LED bar graph for flow indication Enclosure rotatable for optimal operabilit...

Page 2: ...us The actual technical manual includes instructions for installation electrical connection and inauguration as well as the technical data of the device Modifications that answer the purpose of the te...

Page 3: ...ndex Application 4 Function 4 Safety notes 5 Installation 6 Process and environmental temperature 6 Installation notes 6 Installation place 6 Electrical connection 9 Potential equalization earthing 9...

Page 4: ...l The device measures the flow of a liquid medium with the calorimetric measurement method The calorimetric measuring principle is based on cooling a heated temperature sensor Heat is removed from the...

Page 5: ...ce must be chosen resp checked for compatibility with the respective application requirements contacting materials process temperature An unsuitable material can lead to damage abnormal behavior or de...

Page 6: ...treme system or medium temperatures there could exist serious dangers The screw in of the thread process connection by using the terminal housing the connection plug resp the connection cable is not p...

Page 7: ...l pipes Installation in the ascending pipeline for vertical pipes In hygienic applications installation with minimum 3 inclination because of self draining Conditionally recommended orientation Instal...

Page 8: ...pipes open towards the end The sensor tip should never touch the pipe wall Disturbance influence in the pipe system The sensor requires a fully developed flow profile for correct monitoring For this r...

Page 9: ...ion cable For the connection only suitable cables may be used that fulfills the requirements e g regarding temperature chemical resistance or laying at the place of installation Use only shielded sign...

Page 10: ...le free operation In the case of failure or at wire break both electronic switches are opened By using a two channel evaluation besides the flow monitoring also a function dependent monitoring of the...

Page 11: ...scheme Version type GA Conductor color standard connection cable M12 BN brown WH white BU blue BK black The connection cable in not enclosed in the delivery contents Version type WB Conductor color st...

Page 12: ...anufacturer If the device must be sent back for repair the following informations must be enclosed An exact description of the application The chemical and physical characteristics of the product A sh...

Page 13: ...Y others Material process connection probe process wetted V Steel 1 4404 316L resp 1 4571 316Ti Sensor length L1 mm 0 Process connection type 0 2 G 30 mm Process connection type 3 G 28 mm Process con...