Compressed Air Dryer
Models: ACD/SCD
Part Number: 882.03168.00
Bulletin Number: DRY1-600.00
Effective: 03/2014
Page 1: ...Compressed Air Dryer Models ACD SCD Part Number 882 03168 00 Bulletin Number DRY1 600 00 Effective 03 2014...
Page 2: ...___ _________________________ _________________________ _________________________ _________________________ We are committed to a continuing program of product improvement Specifications appearance an...
Page 3: ...A certified copy of our invoice is available upon request The original Bill of Lading is attached to our original invoice If the shipment was prepaid write us for a receipted transportation bill Advis...
Page 4: ...wpoint Operation Optional 11 2 8 Microprocessor Controls 12 Identifying the Controller s Buttons and Indicators 13 Understanding the Controller s Parameters 14 2 9 Restoring Factory Default Settings 1...
Page 5: ...Compressed Air Dryer v CHAPTER 7 APPENDIX 26 7 1 Warranty 26 7 2 Technical Specifications 27 Dryer Operating Parameters 28 Dimensions 29 Spare Parts List 30...
Page 6: ...ter includes a description of electrical and mechanical controls in addition to information for operating the dryer safely and efficiently The Maintenance chapter is intended to ensure that your dryer...
Page 7: ...ty of the handling equipment or cause it to become unstable Carefully test the condition of lifting cables chains ropes slings and hooks before using them to lift a load Be sure that all on current ca...
Page 8: ...ve safety guards Such alteration is not only unsafe but will void the warranty on your equipment When changing control settings to perform a different mode of operation be sure selector switches are c...
Page 9: ...onsidered in the selection of your drying system including type of materials residence time throughput of the extruder or injection molding machine Should your operating environment change the manufac...
Page 10: ...ty of the personnel operating and maintaining the equipment to familiarize themselves with the safety procedures and the proper use of any safety devices High Temperature Safety System A high temperat...
Page 11: ...r of a second plastic that actually separates the water vapor from the air This second coating allows air to pass through it over 20 000 times easier than it allows water to pass As a result moisture...
Page 12: ...sed PID temperature controller for maintaining process air temperature The controller is a modular self contained unit that you can remove from the mounting housing All parameters except for the proce...
Page 13: ...to decrease the set point temperature during operation It also decreases the parameter values in set up modes Up Arrow button The Up Arrow button is used to increase the set point temperature during...
Page 14: ...ariables that had been modified previously The default value is OFF Temperature Input Shift Tns Can be set from 199 9 to 999 9 This setting is used to offset an error between the set point and the act...
Page 15: ...ng Factory Default Settings If the preset parameters on the controller have been tampered with and it no longer properly controls temperature and displays dew point you can restore the controllers to...
Page 16: ...ount it to the hopper Note In some cases depending on the drying hopper model an adapter may not be required If an adapter is not required attach the dryer to the hopper with the clamps provided and i...
Page 17: ...llowing procedure to connect a floor mount dryer to a hopper 1 Using the clamps provided clamp a hose adaptor onto the dryer and the hopper See Figure 4 Note Depending on the drying hopper model the c...
Page 18: ...ressed air supply must be regulated to 80 PSI 5 5 bars Low air pressure will create poor drying performance If the pressure in the system drops below 35 PSI the alarm light will activate and the proce...
Page 19: ...he inlet of the compressed air dryer 2 Attach the large particle filter including the close nipple to the membrane drying kit Note The membrane drying kit must have the large particle and the coalesci...
Page 20: ...Mode Key one time The PV display will read At 3 Press the Up Arrow button to change the value to ON 4 Press the Level button to begin auto tuning and return to the Operation level The unit will automa...
Page 21: ...Arrow button to change the value to RUN 8 Press the Mode button to begin operation 9 After the proper pre drying time for the initial hopper fill has elapsed fully open the drying hopper slide gate No...
Page 22: ...ty 5 2 Cleaning and Replacing the Filters The 10 cfm compressed air dryer uses a large particle air filter in the process air system to clean the compressed air before it enters the drying cabinet The...
Page 23: ...1 Make sure that the main power to the dryer is shut off and locked out 2 Locate the fuse holder that houses the fuse for the dryer see picture below for fuse holder location 3 Using a standard flat h...
Page 24: ...nufacturer s data sheet for proper drying temperature Make sure plant personnel are aware of the correct process temperature set point High temperature alarm not set properly Reset high temperature al...
Page 25: ...trol power fuse for continuity Turn disconnect switch and control power switch ON The key protection switch is set to ON Set the key protection switch to OFF Alarm light is on and unit has no air pres...
Page 26: ...uipment to be returned Reason for requesting the return must be given All returns are to be shipped prepaid The invoice number and date or purchase order number and date must be supplied After inspect...
Page 27: ...40 F 40 C Heating capabilities up to 400 F Large particle compressed air filter Exhaust air cartridge filter 1 16 DIN PID temperature controller High process temperature alarm light Automatic shutoff...
Page 28: ...48 120 2 4 0 16 0 01 4 6 2 1 9 2 4 2 10 4 4 7 PE Filled 185 85 3 4 0 5 0 02 4 6 2 1 9 2 4 2 10 4 4 7 PE 194 90 1 2 0 05 0 01 7 3 2 14 6 4 15 8 7 1 PEEK 302 150 4 3 5 1 6 7 3 2 7 9 3 6 PEI 302 150 4 0...
Page 29: ...Compressed Air Dryer Chapter 7 Appendix 29 of 31 Dimensions 13 4 339 12 25 311 7 3 185 12 305 15 7 398 6 8 172...
Page 30: ...Parts not included in this list must be replaced by the factory Part No Quantity Description 35452 1 Filter Regulator 725 00002 00 1 Fuse 110 volt 725 00001 00 1 Fuse 220 1 50 725 00001 00 2 Fuse 230...
Page 31: ...e Service Department Call toll free 8am 5pm CST 800 423 3183 or call 262 641 8600 Emergencies after 5pm CST call 847 439 5655 We have a qualified service department ready to help Service contracts are...