background image

Page 12 

 

Replacing the Circuit Board Batteries                               

The ATR240 is equipped with (1) CR2032 3v Lithium Coin Cell battery on the Main board.   
The battery should last approximately 1.5 to 2 years under normal operating conditions.   
Do not attempt to replace the battery as it will void your warranty.    If your clock is already 
out of warranty you can attempt to replace the batteries yourself but note that you could 
damage the board if you short out any components on the circuit board.  Avoid using 
metal objects to remove the batteries. 

Note: all Time Recorder settings will be reset to factory defaults as soon as the Main 
board battery is removed. 

 
                                     

Back Case                           Front Case 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

                        Main Board Battery     

 
         

 

1. Unplug clock. 
2.  Remove the front cover and the two screws that connect the front and back case.  

Remove the front case and lay it flat being careful not to pull any wires or cables loose. 

3.  To remove batteries press the metal retaining clip away from the battery. The battery 

should pop up. It may be necessary to use a small probe to pop the battery out. 

4.  Replace the batteries and re-assemble clock. 

 
 

 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for ATR240

Page 1: ...ATR240 User Manual Top Loading Time Card Recorder...

Page 2: ...ur warranty Battery replacement should be done by qualified personnel wearing the proper eye protection CAUTION Danger of explosion if the battery is incorrectly replaced Replace only with the same or...

Page 3: ...8 Internal View 8 Re setting Time Recorder to Factory Defaults 9 Troubleshooting 9 Frequently Asked Questions 10 Maintenance 11 Replacing the Ribbon Cassette 11 Replacing the Circuit Board Batteries...

Page 4: ...int Customer Service at 800 334 7190 3 Connect the ATR240 power adapter and plug it into a wall outlet to turn the clock on Do not attempt to service the ATR240 yourself Disassembling the clock will v...

Page 5: ...07 Sun 01 07 07 Clock Display Format 12 or 24 Hr 12 08 Adjust Printing Position Max 6mm Vert Horiz adj Increase s to move up right 00 15 Vertical Axis 00 30 Horiz Axis 08 08 vert horiz 09 DST Start Mo...

Page 6: ...Clock Overview Top View Front View Battery Status Indicator A fully charged Battery will have 5 bars DST Icon displays when exiting programming mode when DST is turned on Each blink of the colon is o...

Page 7: ...Page 4 Rear View...

Page 8: ...e 9 Press P4 or P5 to select the current date 10 Press P6 to save Setting Time 11 The mode indicator 3 will be flashing press P6 to select 12 Press P4 or P5 to select the current hour 13 Press P6 to s...

Page 9: ...date 32 Press P6 to save 33 Press P4 or P5 to select the correct start time US 2am 34 Press P6 to save 35 Complete steps 29 34 to complete the set up for the end of DST Setting Print Format 36 The mod...

Page 10: ...n Available Auto Column Changing Yes Compatible with Wkly Time Card Yes Card Recognition Off Card Recognition front back Yes Clock Specifications Miscellaneous Input Voltage DC 18v Input Current 1 5A...

Page 11: ...4v Capacity 1800mA Standby mode 30 36hr reserve power Fully charged 5 days use 300 punches day Note Actual battery life depends on many factors such as battery age temperature discharge history etc a...

Page 12: ...e was not set correctly Prolonged power outage Set correct time Set time after power is restored The clock keeps losing time The coin cell battery on the motherboard needs to be replaced Replace the c...

Page 13: ...n will not advance remove cassette and try advancing again If ribbon won t advance replace ribbon Frequently Asked Questions 1 Q The display does not work or parts of it do not work A Possible Causes...

Page 14: ...3 to move the print head to the center of the clock so that the ribbon cassette can be more easily accessed 2 Pull the ribbon holder tabs towards you to unlock the ribbon cassette and use the handle o...

Page 15: ...any components on the circuit board Avoid using metal objects to remove the batteries Note all Time Recorder settings will be reset to factory defaults as soon as the Main board battery is removed Bac...

Page 16: ...o the clock with the wires inserted into the opening in the side of the compartment This is important since the battery door can t be attached if the battery is sitting on top of the wires You may nee...

Page 17: ...a relay is required Please call Acroprint or your Dealer to order the relay PN 01 0230 000 When a signal is activated by the clock the internal contacts of the relay close and complete the circuit Th...

Page 18: ...nual available on web 06 0400 001 ATR240 User Manual available on web 06 0401 000 Mounting Template available on web 09 7000 000 ATR241 Weekly Time Card pack of 250 09 7001 000 ATR241 Monthly Time Car...

Page 19: ...ject to misuse abuse negligence accidents power surges and lightning The guarantee is not applicable if the serial number has been altered defaced or removed or if the device has been tampered with or...

Page 20: ..._____________ Email Address____________________________________________________ So that we may serve you better please indicate your primary business activity 01 Manufacturing 04 Government 02 Wholesa...

Page 21: ...06 0400 001 Rev C...