Environmental
It is recommended this unit be
mounted upright on a DIN rail,
allowing free air to flow into the
bottom vent, pass through the
unit and out the top vent.
Operating Temperature:
-40
C to +80
C (-40
F to +176
F).
Storage Temperature:
-40
C to +85
C (-40
F to +185
F).
Relative Humidity:
5 to 95%, non-condensing.
Altitude:
Up to 2000 meters.
Isolation:
The Input 1/USB, Input 2, Output 1, and Output 2 circuits are isolated from
each other for common-mode voltages up to 250VAC, or 354V DC off DC power
ground, on a continuous basis (will withstand 1500VAC dielectric strength test for
one minute without breakdown). Complies with test requirements of
UL 61010C-1
First Edition, August 9, 2002 “UL Standard for Safety for Process Control
Equipment”
for the voltage rating specified.
Installation Category:
Suitable for installation in a Pollution Degree 2 environment
with an Installation Category (Over-voltage Category) II rating per IEC 1010-1 (1990).
Shock & Vibration Immunity:
Random vibration: Designed to comply with VITA 47
Class V1. Shall withstand vibration from 5 to 100Hz. with Power Spectral Density
(PSD) = 0.04g
2
/Hz, for 1 hour per axis. Testing shall be in accordance with MIL-STD-
810, Method 514, Procedure 1. Mechanical shock: Designed to comply with VITA 47
Class OS1, 20g, 11ms half sine and terminal sawtooth shock pulses. 3 shock pulses in
each direction along 3 axes (36 shocks, total). Testing shall be in accordance with
MIL-STD-810, Method 516, Procedure 1.
Electromagnetic Compatibility (EMC)
Minimum Immunity per BS EN 61000-6-1:
1)
Electrostatic Discharge Immunity (ESD), per IEC 61000-4-2.
2)
Radiated Field Immunity (RFI), per IEC 61000-4-3.
3)
Electrical Fast Transient Immunity (EFT), per IEC 61000-4-4.
4)
Surge Immunity, per IEC 61000-4-5.
5)
Conducted RF Immunity (CRFI), per IEC 61000-4-6.
This is a Class B Product with Emissions per BS EN 61000-6-3:
1)
Enclosure Port, per CISPR 16.
2)
Low Voltage AC Mains Port, per CISPR 14, 16.