Manual of AMC Series intelligent power collection

and monitoring device

Installation and Operation Instruction V3.0

ACREL Co., Ltd.

Summary of Contents for AMC Series

Page 1: ...527 Manual of AMC Series intelligent power collection and monitoring device Installation and Operation Instruction V3 0 ACREL Co Ltd...

Page 2: ...by any means electronic mechanical photocopying recording or otherwise without prior permission of Acrel All rights reserved This company reserve power of revision of product specification described...

Page 3: ...1 Outline and mounting cutout size 3 4 2 Wiring method 4 5 Operating instructions 7 5 1 Explanation for keypad functionality 7 5 2 Display Example 8 5 3 Programming menu 13 5 4 Programming example 15...

Page 4: ...AMC72L E4 KC Three phase voltage Zero sequence voltage Three phase current Zero sequence current Three phase active power Total active power Three phase reactive power Total reactive power Three phase...

Page 5: ...ing output Output mode Relay normally open contact output Contact capacity AC 250V 3A DC 30V 3A Analog output 1 5V 4 20mA Accuracy class Frequency 0 05Hz Current Voltage 0 2 class Reactive power l 0cl...

Page 6: ...cture 3 Outline faceplate size housing size cutout size width height width height depth width height 72 square 75 75 66 5 66 5 94 3 67 67 96 square 96 96 86 5 86 5 77 8 88 88 Figure 1 AMC72 appearance...

Page 7: ...is mounted from the Front to the mounting hole as shown in figure 5 4 Insert the instrument clasp to secure the instrument as shown in figure 6 Figure 5 Figure 6 4 3 Wiring method According to varied...

Page 8: ...g Inputs Common RS485 11 14 Voltage input Current input 4 5 U1 UN I1 I1 three phase single phase Figure 7 AMC72 series terminal block diagram Note Switching input 32 DI3 33 DI4 pulse output 32 E 33 E...

Page 9: ...8 9 11 12 13 14 4 5 6 7 8 9 11 12 13 14 4 5 6 7 8 9 11 12 13 14 4 5 6 7 8 9 L N U1 UN I1 I1 FUSES S1 S2 11 14 4 5 L N U1 UN I1 I1 FUSES S1 S2 11 14 4 5 Single phase Single phase 2 wire 1CT Single phas...

Page 10: ...r switching Display item Under programming mode used for switching same class menu or ones place reduced Right key Under measurement mode used for switching Display item Under programming mode used fo...

Page 11: ...k M V1 1 P V2 2 Q V3 3 k M V1 1 P V2 2 Q V3 3 k M V1 1 P V2 2 Q V3 3 k M V1 1 P V2 2 Q V3 3 k M V1 1 P V2 2 Q V3 3 k M V1 1 P V2 2 Q V3 3 k M V1 1 P V2 2 Q V3 3 k M V1 1 P V2 2 Q V3 3 k M V1 1 P V2 2...

Page 12: ...tive Power Capacitive Reactive Power Switch Voltage k M k M k M k M k M k M k M k M k M k M frequency The K indicator is on indicating that the power unit is kWh When reading the power the second and...

Page 13: ...5 2 3 The steps for viewing various types of power parameters of the AMC72L 96L are shown in Figure 16 17 AMC72L 96L three phase power meter Figure 16 AMC72L single phase power Set Entry Power data P...

Page 14: ...or Power Power Factor Phased active power Phased reactive power Split phase power factor Voltage Phase Angle Date and time Demand and occurrence time 11 26 35 November 19 18 At 11 26 on November 19 th...

Page 15: ...pparent power Figure 19 5 2 5 View the harmonic parameters of the AMC72L 96L meter as shown in Figure 20 Figure 20 Note Only the 96 shape has the function of fractional harmonics press the left and ri...

Page 16: ...5 3 1 Meter general programming menu Table 5 First menu Second menu Tertiary menu Description Start up display selection 0 automatic page turning other page numbers correspond to the current meter mo...

Page 17: ...unication baud rate None 2bit odd even Communication data mode 000000000001 999999999999 645 Protocol Communication Address See 5 4 2 for details Analog output item selection 4 20mA Or 0 20mA Output r...

Page 18: ...Programming example The programming example use flow chart to introduce how to change some options of programming menu such as current times transducer setting etc Note After completing setting or se...

Page 19: ...item selection 00 01 02 03 04 05 06 07 UA UB UC U B UBC UCA IA IB 08 09 10 11 12 13 14 15 IC PA PB PC Psum QA QB QC 16 17 18 19 20 21 22 23 Qsum SA SB SC Ssum PFA PFB PFC 24 25 PF F 4 20mA Or 0 20mA...

Page 20: ...is 220kV 100A 3 38 10kW the output type is 4 20mA if 100 total power the first analog output is 20mA 0 total power The first analog output 4mA the first analog output selection register address 0005H...

Page 21: ...wed when the signal is 0 Lo on is enabled Lo of is forbidden Note 1 Hysteresis setting high alarm value setting and low alarm value setting correspond to the display value of the battery and the displ...

Page 22: ...100V second bit input current range 0 5A 0 1 A Uint16 0003H PT transformation ratio R W 1 9999 Uint16 0004H CT transformation ratio R W 1 9999 Uint16 0005H First analog output parameter setting Analog...

Page 23: ...t and output status R W See 6 2 1 Uint16 0023H high byte Decimal point U DPT R 3 7 Uint16 0023H low byte Decimal point I DCT R 1 5 0024H high byte Decimal point PQ DPQ R 4 10 Uint16 0024H low byte Sym...

Page 24: ...version formula Uint32 0041H 0042H Release active electric energy secondary side R 0 999999999 see 6 2 2 for conversion formula Uint32 0043H 0044H Inductive reactive electric energy secondary side R 0...

Page 25: ...00ACH Event record 5th R See 6 2 3 event record table 10 for details Uint16 00ADH 00B2H Event record 6th R See 6 2 3 event record table 10 for details Uint16 00B3H 00B8H Event record 7th R See 6 2 3 e...

Page 26: ...details Uint16 0169H 016FH Event record 9th R See 6 2 3 event record table 11 for details Uint16 0170H 0176H Event record 10th R See 6 2 3 event record table 11 for details Uint16 0177H 017DH Event re...

Page 27: ...3 decimal places Int16 0115H SA R 0 9999 3 decimal places unit VA Uint16 0116H SB R 0 9999 3 decimal places unit VA Uint16 0117H SC R 0 9999 3 decimal places unit VA Uint16 0118H Ssum R 0 9999 3 deci...

Page 28: ...ion alarm over power value R W 9999 9999 the same as the DO2 setting menu 5 4 3 H P Int16 027EH DO2 combination alarm underpower value R W 9999 9999 L P in the same DO2 setting menu 5 4 3 Int16 027FH...

Page 29: ...ation alarm current overcurrent value R 0000 9999 Uint16 03F4H DO2 combination alarm underpower factor value R 0000 9999 Uint16 03F5H DO2 combination alarm overvoltage imbalance value R 0000 9999 Uint...

Page 30: ...hase voltage 2 31 harmonic distortion rate R 0 9999 2 decimal places example 200 means 2 Uint16 0466H 0483H A Phase current 2 31 harmonic distortion rate R 0 9999 2 decimal places example 200 means 2...

Page 31: ...hase current maximum value and occurrence time R The same as the A phase voltage extreme value Uint16 061CH 061FH B phase current maximum value and occurrence time R The same as the A phase voltage ex...

Page 32: ...ent power collection and monitoring device is relay output which can be remotely controlled by the host computer the remote control has two modes 1 level trigger 2 pulse trigger to realize the remote...

Page 33: ...and the CT is read from the address 0004H Note In general the user reads the absorbed active energy b Read the primary side energy in 0047H 004EH This value uses the floating point variable data type...

Page 34: ...ined alarm type note Address 3 Year Month Address 4 Day Hour Address 5 Minute Second Address 6 The value at the time of the alarm the minimum value of the three phases is recorded when the phase is br...

Page 35: ...age current power etc readings are incorrect Check if the voltage to current ratio setting is correct Check if the wiring mode setting is consistent with the actual Check if voltage transformer curren...

Page 36: ...ax 0086 21 69158303 Web site www acrel electric com E mail ACREL008 vip 163 com Postcode 201801 Manufacturer Jiangsu Acrel Electrical Manufacturing Co LTD Address No 5 Dongmeng Road Dongmeng industria...