background image

Langdale

Woodburning Cast Iron Stove • Model FB6WB

To be retained by the user for future reference

Thank you for purchasing an ACR Heat Products stove

TECHNICAL MANUAL

Document FB6WB 0101 • Version 1 Date 15/03/16

Serial Number:

WOOD

BURNER

SMOKE 

EXEMPT

AIRWASH 

SYSTEM

10

YEAR

10

YEAR

WARRANTY

Langdale Cast Iron FB6 0316-1  15/03/2016  16:25  Page 1

Summary of Contents for FB6WB

Page 1: ...or future reference Thank you for purchasing an ACR Heat Products stove T E C H N I C A L M A N U A L Document FB6WB 0101 Version 1 Date 15 03 16 Serial Number WOOD BURNER SMOKE EXEMPT AIRWASH SYSTEM 10 YEAR 10 YEAR WARRANTY Langdale Cast Iron FB6 0316 1 15 03 2016 16 25 Page 1 ...

Page 2: ...ws Asbestos This appliance contains no asbestos if there is the possibility of disturbing any asbestos in the installation of this appliance then specialist advise must be sought and appropriate precautions taken Metal Parts This appliance may contain sharp metal edges take care when installing or servicing this appliance to avoid personal injury Please use appropriate personal protective equipmen...

Page 3: ...ble materials There must be a minimum clearance of mm at each side and mm at the rear of the appliance from any combustible materials If using single wall flue pipe there must be a clearance of at least 3 times the diameter of the flue pipe e g 125mm diameter pipe 375mm minimum clearance from any combustible materials e g wooden beam Curtains and soft furnishings should be a minimum of 1m away fro...

Page 4: ...s well ventilated during this period The appliance should not be operated in mild weather with smokeless fuel Under certain weather circumstances e g fog the chimney will not draw sufficiently and could cause asphyxiation Either await better weather conditions or burn wood only In the rare event of a malfunction due to overheating or a chimney fire the air slides should be shut down completely and...

Page 5: ...ers and ash that the new fuel charge will ignite in a reasonable period If there are too few embers in the fire bed add suitable kindling to prevent excessive smoke Operating your stove Fuel overloading Never overload the stove it will work very well with two medium sized logs The amount of fuel specified in this manual should not be exceeded overloading can cause excess smoke Daily Maintenance Th...

Page 6: ...t draft Check the flue is not obstructed Fire burns too quickly Too much draft Reduce the air control Excessive draft Install a draft stabiliser Smokes on initial Flue is cold Burn paper and kindling to increase lighting heat in flue Smokes while burning Insufficient draught Check the flue is not obstructed Low heat output Poor quality wood Use seasoned Hardwood this has a Higher calorific value P...

Page 7: ...acket Top 38 03 13612 000 Air Slider Spacer 39 03 18710 000 Air Slider Washer 40 03 22201 041 Air Slider Screw M8X20 41 03 22204 041 Air Intake Retaining Screw M8X35 42 03 19508 000 Leg Retaining Screw M8X25 43 03 16110 000 Heat Shield Retaining Spacer 44 03 19310 000 Heat Shield Retaining Screw M8X12 45 03 76320 000 Leg Levelling Bolt M6X20 46 03 19505 000 Blanking Plate Stud M6X35 47 03 18701 00...

Page 8: ...y and are under no circumstances binding 10 YEAR 10 YEAR WARRANTY With the aim of constantly improving our products all modifications considered necessary may be made without notice This manual is correct at time of printing Our appliances are guaranteed against faults and hidden defects subject to the following conditions The appliance must have been installed by a registered competent installer ...

Page 9: ...ed Unit 1 Weston Works Weston Lane Tyseley Birmingham B11 3RP England Tel 0121 706 8266 Fax 0121 706 9182 E mail enquiries acrheatproducts co uk www acrheatproducts co uk Langdale Cast Iron FB6 0316 1 15 03 2016 16 25 Page 16 ...