The installer has a responsibility under the Health and Safety at Work Act 1974 to provide 
for the safety of persons carrying out the installation. Attention is drawn to the fact that fire 
cement is caustic and hands must be washed thoroughly after use. The appliance is heavy 
and  care  must  be  taken  during  handling.  Although  the  appliance  does  not  contain  asbestos 
products,  it  is  possible  that  asbestos  may  be  disturbed  in  existing  installations  and  every 
precaution must be taken. 

 
These instructions give a guide for the installation of the appliance but in no way absolves 
the installer from responsibilities to conform to British Standards, in particular BS8303

BS8303

BS8303

BS8303 and 

BS EN 15287:2007

BS EN 15287:2007

BS EN 15287:2007

BS EN 15287:2007

,  relating  to  the  installation  of  solid  fuel  appliances.  All  local  regulations, 

including those referring to National and European standards need to be complied with 
when installing the appliance. 
 
 
 
 

 

 

 

 

 
 
 
 
The  successful  operation  of  these  appliances  relies  on  the  adequate  performance  of  the 
chimney to which it is connected. The chimney must: 

 

• 

Have  an  internal  cross  section  of  no  less  than  320cm

2

  (200mm  dia).  If  a  flue  liner  is 

used it should be 125mm diameter (5") and suitable for solid fuel. 

 

• 

Be a minimum 4.6m high from hearth level to pot. 

 

• 

Be terminated at least 1m above roof level so that the chimney does not terminate in a 
pressure zone (see Fig. 2). 

 

• 

Be free from cracks, severe bends, voids and obstructions. 

 

• 

Be connected to this one appliance only. 

 

• 

New chimneys must be tested in accordance with HETAS requirements. 

 

• 

If the stove is installed as a free standing appliance, it should not support any part of 
the chimney. 

 

• 

Voids in the chimney should be avoided, as these will prevent a steady flue draught. 

 

• 

The stove flue pipe should pass beyond the narrowing of the chimney (see Fig. 1). 

 

• 

Consideration should be given to falling soot. For rear outlet stoves it may be necessary 
to provide a soot catchment area in the flue pipe so that soot does not settle in the path 
of the flue gases. The optional rear flue box attachment available from ACQUISITIONS 
has a detachable base that allows for fallen soot to be removed (See Fig. 1). 

 

• 

A flue/chimney access point may also be required so that the state of the chimney can 
be checked and any fallen soot removed. 

 

• 

External flues must be insulated to prevent heat loss. 

 

INSTALLATION INSTRUCTIONS 

CHIMNEY & FLUE 

Parts  of  the  appliance,  especially  the  external  surfaces,  will  be  hot  to  touch 

when in operation and due care will need to be taken. 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

• 

Properly installed, operated and maintained, this appliance will not emit fumes into 
the dwelling. However occasional fumes from de-ashing and re-fuelling may occur. 
Persistent  fume  emission  is  potentially  dangerous  and  must  not  be  tolerated.  If 
fume emission does persist, open doors and windows to ventilate the room. Let the fire 
burn out or eject and safely dispose of fuel from the appliance. Once the fire is cold, check 
the flue and chimney for blockages and clean if required. Do not attempt to relight the 
fire  until  the  cause  of  the  fume  emission  has  been  identified  and  corrected.  Seek 
expert advice if necessary. 

 

• 

Do not fit an extractor fan in the same room as the appliance. 

 

• 

An  adequate  air  supply  for  combustion  and  ventilation  is  required.  As  this  stove 
does not exceed 5.0kW nominal heat output (Refer to Building Regulations  Document 
J) a purpose provided air vent is not normally required. However, in certain circumstances 
a purpose provided air vent may be necessary - for example, small or tightly sealed 
rooms. Air openings provided for this purpose must not be restricted. 

 

• 

It  is  important  that  flue  ways  are  cleaned  frequently  and  the  chimney  swept  regularly. 
Also  the  stove  must  be  maintained  in  good  mechanical  order.  Regular  sweeping 
means at least once a year for smokeless fuel and a minimum of twice a year for other 
fuels. 

 

• 

If the chimney was previously used for an open fire, it is possible that the higher flue gas 
temperatures generated by the stove may loosen deposits that were firmly adhering to the 
inner surface of the chimney and cause blockage of the fluepipe. We recommend that 
in such a situation a second sweeping of the chimney should be carried out within one 
month  of  regular  use  of  the  stove  after  installation.  Also,  lock  or  remove  any  existing 
dampers in the flueway. 

 

• 

Should it be likely that children, aged or infirm people approach the fire, then a fireguard 
should be fitted. 

 

• 

Avoid the use of aerosol sprays in the vicinity of the stove when it is in operation. 

 

• 

This appliance must be installed as per these instructions and regulations complied with. 
No modifications or alterations of any kind are permitted. 

 

CONTENTS 

GENERAL SAFETY NOTES 

General Safety Notes 

Page 2 

Installing the Stove 

Page 6 

Installation Instructions 

Page 3 

Operating Instructions 

Page 8 

Chimney & Flue 

Page 3 

Wood Burning 

Page 8 

Flue Draught 

Page 5 

Maintenance 

Page 11 

Flue Stabiliser 

Page 6 

Technical Information 

Page 11 

Dimensions & Clearances 

Page 6 

Guarantee 

Page 12 

Summary of Contents for Bloomsbury SE

Page 1: ...OMPLAINT If you have cause for dissatisfaction with your stove you should first contact your ACQUISITIONS dealer who will bring your concerns to our attention We will assess the nature of the complaint and either send replacement parts for your dealer to fit or nominate a regional engineer to inspect the appliance and carry out any remedial work that may be necessary If the fault is not actually d...

Page 2: ... the appliance especially the external surfaces will be hot to touch when in operation and due care will need to be taken 2 Properly installed operated and maintained this appliance will not emit fumes into the dwelling However occasional fumes from de ashing and re fuelling may occur Persistent fume emission is potentially dangerous and must not be tolerated If fume emission does persist open doo...

Page 3: ...e chimney Chimney too short Extend the chimney Down draught Relocate extend chimney terminal Fit an anti down draught cowl Chimney diameter too large Line the chimney Chimney obstruction Clear sweep the chimney Restricted air supply Check for competing draughts other chimneys extractor hoods fans Fit an air vent if the room is sealed CAUSE REMEDY External wind conditions combined with chimney term...

Page 4: ...ical All flue pipe sections should be as close to vertical as possible 3 All joints in the flue system must be effectively sealed 4 All flue sockets must face upwards 5 Check the appliance for soundness of seals between castings and main components and that all supplied parts and fittings are correctly fitted On completing the installation check that all the internal components of the stove are po...

Page 5: ...rather than below The air supplied above the fire bed provides the oxygen necessary for the volatile gases smoke given off by the wood as it heats to combust This ensures that the gases are burnt and used to heat the stove instead of being wasted up the chimney or condensing and forming tarry deposits inside the stove in the flue or on the stove glass Running the stove with the primary air control...

Page 6: ...ry with each installation and so gaining experience operating your stove is the only way to learn its best operation The stove as with any other metal products will expand and contract A ticking noise may occur This is normal for this type of appliance 11 CLEANING THE STOVE The stove should only be cleaned when it is cold The exterior can be dusted with a firm brush Do not use a cloth as this will...