Acqua SPRINT 1.5 Maintenance Schedule Download Page 1

 

Page 1 of 2 

 

SPRINT 1.5 SURFACE-MOUNTED AERATOR 

MAINTENANCE SCHEDULE 

Water Treatment

 

 
 

The 

Acqua & Co.

  SPRINT  1.5  surface-mounted  aerator  is  a  high  efficiency  machine  designed  to  allow 

continuous operation in outdoor ponds and lakes. Due to its short motor shaft design and effective sealing 
arrangement, the SPRINT 1.5 has a low maintenance requirement. 
 
However, it is important to provide effective preventative maintenance to ensure a long life from the aerator. 
It  is  recommended  that  an  inspection  of  the  primary  seal  is  performed  yearly,  with  inspection  of  the 
secondary  seal  and  bearings  performed  every  two  years.  It  is  recommended  that  the  maintenance 
schedule  provided  be  followed,  using  only  genuine 

Acqua & Co.

  spare  parts,  to  ensure  effective 

management of your asset. 
 

Annual (Yearly) Maintenance

 

 
Annual maintenance is required to inspect the condition of the mechanical seal and clean the unit. Please 
refer  to 

Acqua & Co.

  Aeratore  Sprint  1.5  hp  1

o

  ed.  04/05  Diagram and Spare Parts List for reference as 

required.  
 
a)  Remove and inspect propeller (Part No. 23) by removing cap (Part No. 56) and screw (part no. 89).   
 
b)  Drain paraffin oil from motor casing by removing plug (Part no. 95).  
 
c)  Remove front flange (Part No. 18) and inspect mechanical seal (Part No. 47) and insulation tube (Part 

No.  52)  on  rotor.  The  mechanical  seal  should  be  inspected  to  ensure  that there are no scratches or 
marks on the carbon face or stationary face. The insulation tube should be examined for marking and 
scoring. Replace parts as necessary. 

 
d)  Reassemble all parts ensuring oil is added in the zone between the central housing (Part No. 17) and 

the front flange (Part No. 18). O-ring (Part No. 51) is to be replaced on reassembly. Oil to be used is 
Medicinal Paraffin Oil Light, Food Grade. 

 
e)  Clean  floats  and  motor  to  remove  all  algae,  barnacle,  and  other  build-up  before  returning  unit  to 

service. 

 