background image

WWW.ACORNSAFETY.COM

 

 

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

 

 

 

HEAT TRACED SHOWER

 

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER

1.800.591.9360

TECHNICAL ASSISTANCE FAX: 1.626.855.4894

ACORN SAFETY

P.O. BOX 3527
CITY OF INDUSTRY, CA 91744-0527

UNITED STATES OF AMERICA

Manual #7109-208-001

 

Models:   S1360-HT

Revised: 11/12/18

This warranty does not cover installation or labor charges and does not apply to materials, which have been 
damaged by other causes such as mishandling or improper care or abnormal use. The repair or replacement of the 
defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Acorn™ under this warranty. 
Acorn™ shall not be liable under any circumstances for incidental, consequential or direct charges caused by defects 
in materials, or any delay in the repair or replacement thereof. This warranty is in lieu of all other warranties 
expressed or implied. Product maintenance instructions are issued with each unit and disregard or non-compliance 
with these instructions will constitute an abnormal use condition and void the warranty. Stainless steel must be 
protected on job sites during construction and must be properly maintained after the water has been introduced into 
the safety product or Acorn's™ warranty is void.

1. Please leave this documentation with the owner of the fixture when finished.

2. Please read this entire booklet before beginning the installation.

NOTES TO THE INSTALLER:

LIMITED WARRANTY

UNITED STATES AND CANADA

3. Check your installation for compliance with plumbing, electrical, ANSI Z358.1 and 

other applicable codes.

Acorn Safety warrants that its products are free from defects in material or workmanship under normal use and 
service for a period of one year from date of shipment or 18 months after the date of shipment from factory, 
whichever comes first. Acorn's™ liability under this warranty shall be discharged solely by replacement of repair of 
defective material, provided Acorn

 is notified in writing within one year from date of shipment, F.O.B. Industry, 

California.

 

Acorn Safety

 

a division of Acorn Engineering Company™

Summary of Contents for S1360-HT

Page 1: ...ued with each unit and disregard or non compliance with these instructions will constitute an abnormal use condition and void the warranty Stainless steel must be protected on job sites during constru...

Page 2: ...ve unwanted debris from the lines and prevent unwanted blockages in the safety equipment 5 All employees at risk of contamination should be informed and trained in the use of this and any other safety...

Page 3: ...n Safety a division of Acorn Engineering Company Installation Operation Manual SHOWER SPRAY PATTERN 20 508 SPRAY PATTERN 34 435 8 32 821 CLEAR ZONE GENERAL NOTES 1 ALL DIIMENSIONS ARE IN INCHES MM 2 A...

Page 4: ...d Combination Station Eye Face Wash Plastic Showerhead Drench Hose S1360 HT 84 7 16 645 8 42 235 8 883 8 93 4 8 FREEZE PROTECTION VALVE INSTALL OPPOSITE SUPPLY 1 1 4 NPT OPTIONAL SUPPLY LOCATION GENER...

Page 5: ...ns STEP TWO SUPPLY AND SANITARY DRAIN CONNECTION 2 Make sure proper drainage is supplied nearby 1 Install necessary pipe fittings supplied by others to make connection to 1 NPT supply union w potable...

Page 6: ...rn Engineering Company Installation Operation Manual DETAIL VIEW EXPLODED VIEW FPV CABLE TIES OR FIBERGLASS TAPE BY OTHERS 1 2 NPT X 1 2 ID TUBE BARBED 1 2 14 ANTI FREEZE VALVE 1 2 14 X 1 1 2 L Galv N...

Page 7: ...OPEN AND BLEED WATER UNTIL THE VALVE TEMPERATURE INCREASES THIS CAN BE REMEDIED BY SUPPLYING TEMPERED WATER TO THIS UNIT MAKE SURE THAT HEAT TRACE CABLE HAS HAD TIME TO WARM UP BEFORE TESTING WITH COL...

Page 8: ...The route and area surrounding the Drench Shower should be clear and unobstructed the sooner a person has rinsed off any contamination the less likelihood of injury Drench Shower stations should be lo...

Page 9: ...obstructed the sooner eyes are flushed the less likelihood of damage Eye Wash stations should be located in close proximity to the hazard and take no more than 10 seconds to reach In the case of sever...

Page 10: ...ation Operation Manual Manual 7109 208 001 Revised 11 12 18 Page 10 of 11 Acorn Safety a division of Acorn Engineering Company 1 2 3 4 5 6 7 8 9 10 29 28 27 26 23 22 21 9 20 19 18 17 16 15 14 13 12 25...

Page 11: ...008 000 3 8 16 ZINC PLATED NUT 14 7100 400 000 PUSH HANDLE LABEL 15 7106 407 199 ACTIVATOR PUSH HANDLE HT TRACE 16 7100 325 000 S S 1 1 4 x1 2 NPT REDUCING BUSHING 17 1974 001 000 1 2 14x1 5 L GALV NP...