background image

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER

1.800.591.9360

TECHNICAL ASSISTANCE FAX: 1.626.855.4894

WWW.ACORNSAFETY.COM

 

 

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

 

 

 

 

P.O. BOX 3527
CITY OF INDUSTRY, CA 91744-0527

UNITED STATES OF AMERICA

ACORN SAFETY

Models S0000-AL3

LIMITED WARRANTY

UNITED STATES AND CANADA

Acorn Safety warrants that its products are free from defects in material or workmanship under normal use and 
service for a period of one year from date of shipment. Acorn's liability under this warranty shall be discharged solely 
by replacement of repair of defective material, provided Acorn is notified in writing within one year from date of 
shipment, F.O.B. Industry, California.

This warranty does not cover installation or labor charges and does not apply to materials, which have been 
damaged by other causes such as mishandling or improper care or abnormal use. The repair or replacement of the 
defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Acorn under this warranty. 
Acorn shall not be liable under any circumstances for incidental, consequential or direct charges caused by defects in 
materials, or any delay in the repair or replacement thereof. This warranty is in lieu of all other warranties expressed 
or implied. Product maintenance instructions are issued with each unit and disregard or non-compliance with these 
instructions will constitute an abnormal use condition and void the warranty. Stainless steel must be protected on job 
sites during construction and must be properly maintained after the water has been introduced into the safety product 
or Acorn's warranty is void.

3. Check your installation for compliance with plumbing, electrical, ANSI Z358.1 and 

other applicable codes.

1. Please leave this documentation with the owner of the fixture when finished.

2. Please read this entire booklet before beginning the installation.

NOTES TO THE INSTALLER:

  

Acorn Safety

 

a division of Acorn Engineering

Manual #7109-305-001

Revised: 12/10/18

Summary of Contents for S0000-AL3

Page 1: ...cement of the defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Acorn under this warranty Acorn shall not be liable under any circumstances for incidental conseq...

Page 2: ...3 Flush water supply lines prior to installation This will remove unwanted debris from the lines and prevent unwanted blockages in the safety equipment Page 2 of 9 Acorn Safety a division of Acorn En...

Page 3: ...50 6 MIN 150 125 250VAC 5A DPDT DOUBLE POLE DOUBLE THROW FLOW SWITCH GENERAL NOTES 1 ALL DIMENSIONS ARE IN INCHES MM 2 FLOW SWITCH SHALL BE INSTALLED VERTICALLY WITH HORIZONTAL FLOW 3 DIRECTION OF WAT...

Page 4: ...ELECTRICAL WIRING S0000 AL3 WIRE AND CONNECTORS BY OTHERS WIRE AND CONNECTORS BY OTHERS EXISTING WIRES NOTES NC WHITE BLACK BLACK BLACK NO C GREEN WHITE BLACK TOP LIGHT SIGNAL LIGHT SIGNAL GREEN HORN...

Page 5: ...LECTRICAL WIRING WIRE AND CONNECTORS BY OTHERS WIRE AND CONNECTORS BY OTHERS EXISTING WIRES NOTES NC WHITE BLACK BLACK BLACK NO C FLOW SWITCH GREEN WHITE BLACK TOP LIGHT SIGNAL LIGHT SIGNAL GREEN HORN...

Page 6: ...3 and at least 6 from closest fitting l Flow Switch direction of flow is indicated on switch body SUPPLIES REQUIRED not provided by Acorn l Use hand tools and wrenches in a manner which will prevent...

Page 7: ...locate the alarm near emergency equipment and in a manner that would allow it to be readily visible by employees and quick reaction or emergency personnel when activated 3 Connect wiring supplied by o...

Page 8: ...h Push silencing button while alarm is active the horn should stop sounding and the strobe should continue to flash To reset ASW Silencing Switch Pull button firmly an audible pop should be heard and...

Page 9: ...arm should the unit fail to operate Do not attempt repair MAINTENANCE Perform visual inspection and an operational test twice a year ITEM PART NUMBER DESCRIPTION 1 7103 115 000 ALARM AMBER STROBE WITH...