26
Backflow stops and Cleaning pipes Triplex
For your safety
1 For your safety
Read the instructions before installing and using the backflow stop (cleaning pipe)
to avoid personal injury and damage to property.
1.1 Planning
EN 12056-1 (5.5.2 Flooding within the building drainage system):
"The design of a draining
system shall minimize the risk of blockage with normal predictable usage of the system. The
design of drainage systems shall avoid cross-flow from one sanitary appliance to another."
EN 12056-1 (5.5.3 Flooding prevention):
"Wastewater collected or stored below flood level
shall be discharged into the drainage system via an automatic wastewater lifting plant. In
exceptional cases, anti-flooding valves may be permitted (see EN 12056-4)."
In the absence of any other specifications regarding the backflow level (e.g. in local byelaws
governing public drainage systems), it is deemed to be the top of the road surface where the
sewer connection is located.
NOTICE
Backflow stops are designed for domestic use and may only be used if local
building regulations and the following requirements according to EN 12056-4 are adhered to:
■
Gradient from the drainage line into the sewerage system.
■
Flooding does not present a health hazard or threaten valuable property.
■
There are only a small number of users and they have a WC available above the backflow
level.
■
Use of the connected drainage points can be suspended in the event of a backflow.
Incorrect installation:
NOTICE
Incorrect installation may lead to
self-flooding and backflow if drainage points
above the flood level are routed to a backflow
stop.
Netzbetrieb
1x: Ton ausTest Betriebsverschluss
1x: Zufahrt
2x: Auffahrt
2x: Grundeinstellung
nach Störung
Dauerleuchten
Ausschalten
1. Netzstecker ziehen
2. Tasten (links/rechts)
gleichzeitig
5 Sekunden lang
drücken.
Einschalten
3. Netzstecker ein-
stecken um
Initialisierung
zu starten.
Blinkleuchten
Akkubetrieb
Rückstau
Betriebsverschluss zu
Motorstörung
Akkustörung
Betriebsverschluss fährt auf/zu
Backflow level