background image

Tel. +49 (0) 36965 819–0

 

Fax +49 (0) 36965 819–361

1

I n s t a l l a t i o n   n o t e s

ACO  H a u s t e c h n i k

Service-Line

0150.27.44

As per: 04/2010

 This operating-/assembly instruction applies for the 

ACO Showerdrain Lightpoint LED bath drain illumina-

tion and contains important information! It must be 

handed out to the end user who must keep it in a safe 

place! 

 ACO ShowerDrain Lightpoint

Function description 

The ACO ShowerDrain Lightpoint illumination system consists of one 
accumulator-operated LED module and a charging device. The LED 
module is mounted in the top section of ACO bath drains (refer to 
page 2).

In the case of water entering the drain, the module is activated 
automatically and, with a continuous water inflow, it lights for max. 
15 minutes. In the case of a renewed water inflow, the LED module 
switches on again only after it air-dried before.  

If the shower water inflow stops after less than 15 minutes, the 
module still lights for a period of approx. two minutes, before the 
module switches off automatically.

Charging process prior to initial use

Prior to initial use, the LED modules must be fully charged. This pro-
cess may take up to 18 hours. It must be made sure that the metal 
contacts of the LED modules are free from dust, dirt and moisture. 

Charging process during use

Depending on frequency of use, the LED modules must be rechar-
ged every three months. Before the LED module is inserted in the 
charging device, it has to be cleaned with warm water and to be 
completely dried thereafter. The metal contacts of the LED module 
must be free from dust, dirt and soap residues.

Inserting the LED module in the charger  

Each LED module leg may be inserted into the charging device. Ple-
ase pay attention that the module is correctly inserted. The correct 
positioning can be taken from below illustration. 

Control lamps at the charging device

Charging lamps‘ state

Normal blinking  

Rapid blinking

Permanent lighting

Meaning

Charging of LED modules takes place 

Accumulator voltage already intensely dropped 

or accumulator damaged. The charging device 

nevertheless tries to recharge this LED module. 

If, during the charging process, the charging 

device does not switch over to slow blinking 

(normal charging) within one hour, the LED mo-

dule is defective and may no longer be used.

Charging process finished

 

Art. no. of top section 

Minimal installation height

 

 

(Upper edge of drain body to upper edge of grating)  

            

 

5141.22.00 60 

mm

  

5141.23.00 

60 mm

 5141.25.00 

60 

mm

 5141.29.00 

95 

mm

 5141.30.00 

95 

mm

 5141.32.00 

95 

mm

 5141.46.00 

60 

mm

 5141.42.00 

95 

mm

 5141.43.00 

60 

mm

 5141.48.00 

95 

mm

Suitable for following ACO top sections 
with minimal installation heights

 Lighting 

kit 

  

red 

Art. no. 9010.89.10

 

blue 

Art. no. 9010.89.11

 

green 

Art. no. 9010.89.12

 

warm-white 

Art. no. 9010.89.13

Summary of Contents for ShowerDrain Lightpoint

Page 1: ...ing use Depending on frequency of use the LED modules must be rechar ged every three months Before the LED module is inserted in the charging device it has to be cleaned with warm water and to be completely dried thereafter The metal contacts of the LED module must be free from dust dirt and soap residues Inserting the LED module in the charger Each LED module leg may be inserted into the charging...

Page 2: ... internal socket of the top sec tion prior to fitting the LED module Insert module slantly Pull the third leg upwards Carry out height positioning Pull module upwards until it gets caught automatically It must be observed that approx 10 mm clearance remain between upper edge of grating and the upmost place of the Lightpoint This guarantees safe draining of water ...

Page 3: ...ay therefore not be disassembled Repair works must always be carried out by an authorised service center or a specialist as otherwise you risk destruction of the product Moreover the approval CE as well as warranty claims expire Prior to cleaning unplug the mains plug Technical data Wall power supply Input 230 V Output 9 V DC 800 mA Charging device Input 9 V DC 300 mA Charging current 250 mA typ C...

Page 4: ...ed Do not expose to direct sunlight Never operate the charger unattendedly A different use as the one described before leads to damage of this product Moreover risks as short circuit combustion electric shock and alike persist The product as a whole may not be changed or altered The charger may only be operated in dry interior rooms Don t leave the packing material carelessly as it could become a ...