Tel. +49 (0) 36965 819–0
Fax +49 (0) 36965 819–361
1
I n s t a l l a t i o n n o t e s
ACO H a u s t e c h n i k
Service-Line
0150.27.44
As per: 04/2010
This operating-/assembly instruction applies for the
ACO Showerdrain Lightpoint LED bath drain illumina-
tion and contains important information! It must be
handed out to the end user who must keep it in a safe
place!
ACO ShowerDrain Lightpoint
Function description
The ACO ShowerDrain Lightpoint illumination system consists of one
accumulator-operated LED module and a charging device. The LED
module is mounted in the top section of ACO bath drains (refer to
page 2).
In the case of water entering the drain, the module is activated
automatically and, with a continuous water inflow, it lights for max.
15 minutes. In the case of a renewed water inflow, the LED module
switches on again only after it air-dried before.
If the shower water inflow stops after less than 15 minutes, the
module still lights for a period of approx. two minutes, before the
module switches off automatically.
Charging process prior to initial use
Prior to initial use, the LED modules must be fully charged. This pro-
cess may take up to 18 hours. It must be made sure that the metal
contacts of the LED modules are free from dust, dirt and moisture.
Charging process during use
Depending on frequency of use, the LED modules must be rechar-
ged every three months. Before the LED module is inserted in the
charging device, it has to be cleaned with warm water and to be
completely dried thereafter. The metal contacts of the LED module
must be free from dust, dirt and soap residues.
Inserting the LED module in the charger
Each LED module leg may be inserted into the charging device. Ple-
ase pay attention that the module is correctly inserted. The correct
positioning can be taken from below illustration.
Control lamps at the charging device
Charging lamps‘ state
Normal blinking
Rapid blinking
Permanent lighting
Meaning
Charging of LED modules takes place
Accumulator voltage already intensely dropped
or accumulator damaged. The charging device
nevertheless tries to recharge this LED module.
If, during the charging process, the charging
device does not switch over to slow blinking
(normal charging) within one hour, the LED mo-
dule is defective and may no longer be used.
Charging process finished
Art. no. of top section
Minimal installation height
(Upper edge of drain body to upper edge of grating)
5141.22.00 60
mm
5141.23.00
60 mm
5141.25.00
60
mm
5141.29.00
95
mm
5141.30.00
95
mm
5141.32.00
95
mm
5141.46.00
60
mm
5141.42.00
95
mm
5141.43.00
60
mm
5141.48.00
95
mm
Suitable for following ACO top sections
with minimal installation heights
Lighting
kit
red
Art. no. 9010.89.10
blue
Art. no. 9010.89.11
green
Art. no. 9010.89.12
warm-white
Art. no. 9010.89.13