63
Maintenance
Assembly of components
£
Insert operating seal (6) and emergency
seal (7) in housing. Pay attention to
correct seating of sealings, it must
be possibe to open the flaps in flow
direction.
6
7
£
Apply cover (8) to housing.
Q
Adjust lever for emergency seal verti-
cally, to enable lever to slide in guide (9.)
8
9
£
Tighten screw joint of cap nuts in
sequence indicated (10) (fastening
torque 5 - 8 Nm).
£
After assembly of components is
completed, continue with sequence of
works as mentioned in chapter 8.
5
10