48
Installation
6.4.4 Connection of pressure hose
The pressure hose (6) is included in scope of supply and is 5 m long.
CAUTION
The pressure hose (6) must be laid permanently rising and frostproof, as
condensation water could affect its function.
Keep screw cap (11) for maintenance/functional test.
Connection at backflow stop
£
Cut off both hose plugs at pressure hose
(6) with the help of a cutter.
£
Loosen spigot nut (12) and remove
screw cap
£
Slide spigot nut over hose end and put
onto hose connection socket at backflow
stop (13), screw down with spigot
nut. When screwed down properly,
connection is in accordance with
protection type IP 68.
11
12
13
Connection at control
£
Lay pressure hose permanently rising,
if required carry out expert length
adaptation.
£
Loosen spigot nut of pressure line
connection (1) and slide over other
pressure hose end.
£
Put hose in pressure line connection (1)
and fix with spigot nut.
CAUTION
Malfunction possible if length
adaptation was not carried out expertly.
£
Cut off line (6) with the cutter (14)
perpendicularly.
1
14
1
6