25
Product description
Accumulator check
The accumulator is checked permanently for too high charging
voltage (accumulator missing, fuse defective, accumulator defective)
and low voltage (cell defective, cell of accumulator discharged).
Fault signal is carried out in two stages:
First stage: The accumulator loses capacity, but is still fully
functioning:
The red LED 4 (4) flashes every 8 seconds. In addition,
a warning signal sounds every 30 seconds.
Seond stage: Accumulator defective
The red LED 4 flashes every 4 seconds. In addition, a
warning signal sounds every 2 seconds.
CAUTION
If the accumulator must be exchanged, this may only be
carried out by an electrician. The accumulator has two connections
which must not be mixed up. The circuit board can be destroyed by
discharge.
Accumulator
Cable
Terminal strip
(+)
red
Accumulator (+)
(-)
black
Accumulator (-)
(
chapter 9.2)