ACO QuARTz Installation & Operation Download Page 1

ACO  L i g h t l i n e

QuARTz by ACO 
ShowerDrain Lightline
Installation & Operation

Product Description 

ACO Lightline contains two low-voltage battery-operated LED units which fit directly into the 
QuARTz   by ACO ShowerDrain channel grating. These units will come on automatically as 
soon as they come in contact with water and will come off approximately two minutes after 
the shower is turned off.

Charging the LED Unit

The LED unit must be fully charged before installing for the first time. Make sure the LED 
unit is clean and dry, then insert it into the charger as shown in the picture below. Note the 
LED unit profile orientation before fitting it into the charger.

Connect the main adaptor to the charger and turn the power on. Control indicators will begin 
to blink. The charging process can take up to 18 hours to complete.

Note

The Indicators will blink quickly if the energy 
level in the LED unit is low. If the indicators 
continue to blink quickly for more than one 
hour, then the LED unit is defective and 
should be replaced.

Under normal conditions of use, a fully char-
ged module should last approximately three 
months before needing a replacement.

For optimum performance, always keep 
the LED unit fully charged to preserve their 
lifespan.

Control indicators

Installing the LED Unit 

1. Remove the grating form the shower 
channel.

2. Remove the grating plastic locks from 
the sides of the grating and insert the LED 
unit making sure that the LEDs are facing 
toward the center of the grating while the 
angled top faces upward allowing water to 
drain freely.