INSTALLATION MANUAL FOR PRO I/O, PRO I/O–60

GENERAL INFORMATION 

PRO-I/O and PRO-I/O-60 modules are optional extension
modules   for   PRO   system   with   relay   output   and   switch
output.   Both   modules   have   equal   function,   difference
between them is only visual. 
PRO-I/O module has standard ACO housing, possible to
suface mount (dimensions: 71x70,5x19,4 mm) and it has
Rj45 socket and screw terminals for connecting the wires.
PRO-I/O-60   is   equipped   only   with   screw   terminals   for
wires   connection,   the   size   (cross-sections   is   50   mm)
allows putting the module into 60 mm electric back boxes.
PRO-I/O module optionally extends the system with relay
output and normally  open (NO) input. The latter can be
used   to   call   certain   receivers   (from   additional   door   bell
button)   or   from   remote   opening   activation   (typical
activation of e-lock).
NC/NO   contact   points   work   either   in   monostable   or
bistable mode and they can be used to control additional
gate, lights or external calling signal can be connected to
it.

In   case   call   incoming   from   the   I/O   module   the   receiver
shows the picture from the camera (if available) and starts
to ring. Calling from the I/O module is shown by pulsating
key icon and lasts for 10 s. and the receivers with handset
ring with different tone. In order to enable the relay in the
I/O module use F2 button (circle icon). Any action at the
receiver during incoming call from the module cancels the
call and enables the desired action. When the call signal
mode is enabled, the I/O module enables the relay while
there is call from the panel and when the module's input
gets the contact, the  I/O module will automatically open
the door. When the input has a permanent contact, every
call from the panel will enable the relay for 1 s and will
open the door.The module can work also as a relay and
trigger   the   e-lock   for   the   time   set   in   the   outside   unit,   it
doesn't concern opening from the INPUT function of the
outside   station   (this   feature   is   available   in   the   software
version   of   the   module   2.1   and   the   panel's  version   from
v.1.1.5)

TECHNICAL PARAMETERS

Power voltage

 15VDC ±5%

Max. power consumption

 35mA

Power consumption in standby

 ~0,14W

Contacts load

 5A/250VAC

Type of external trigger

 NO switch

Resistance

 ≤ 20Ω

Contacts type

NO/NC with common point COM

Sockets type

RJ45 socket / screw terminals ARK

Work mode

monostable / bistable

Additional calling type

 Normally open (NO)