Opening with additional push button

 

The panel features an additional INPUT, which is configured by default as additional opening - when 
shorted to ground it activates door opening. Such opening while the call is pending completes the 
procedure of calling the apartment. 
This  input  can  be  connected  to  any  NO  button  such  as  INS-OB,  code  lock,  card  access  reader, 
motion  detector  etc.  The  input  is  protected  against  a  permanent  circuit  short-circuit  (short  circuit 
triggers it’s disconnection from the system until released). 

 

 

Further door opening

 

 

The slave panel features the so called a further door opening function. If the master panel opens the 
door and terminates the call or opens the door with an access code or proximity key fob, the waiting 
time is automatically activated in the next slave panel. During this time, pressing any button (except 
"#") activates door opening. This option is enabled only in those slave panels through where the call 
originated or which must me used (passed) to reach the apartment assigned to the access code or 
proximity key fob used. Standby mode can be cancelled with the "#" button. If the parameter "Open 
after delay" is activated, after the pre-set delay time has passed the door will be opened automatically 
without pressing any key. The wait time is set in each slave panel. The further door opening pulse 
must be enabled on the master panels. The function is disabled in the panels' default settings and 
can be enabled using the software. 

 

 

Opening using the input from the additional module

 

 

The panel can be used for opening via an additional module, such as an I/O module. The module is 
connected to the EXTMOD socket on the panel board and configured via the PC program. 

 

 

 

Automatic opening when calling an additional number

 

 

If the "Auto door opener" function is enabled (for additional number only) and the handset is not hung 
up (picked up), door opening will be activated automatically after the first ringing signal. If the handset 
was hung up during the first ringing tone, the panel works normally - the handset can be picked up 
and communication is possible. The automatic opening function is commonly used in commercial 
buildings 
- letting people in is done by simply lifting the handset; after business hours the handset is hung up 
and the door entry unit works normally. For this purpose, the recommended receiver model is INS-
UP720B/XM.  For  certain  active  receivers  (for  example  UP800/MP800/INS-MP7)  it  is  possible  to 
activate the auto-opening function independently. 

 

Additional numbers.

 

Two  additional  supported  numbers  can  be  added  for  the  ringing  operation  mode  using  numeric 
keypad  buttons.  These  can  be  any  number  in  the  range  of  1-999  (disabled  by  default),  to  which 
physical  addresses  of  receivers  can  be  assigned.  Additional  numbers  can  assigned  to  the  same 
receiver so that it can be called using three different numbers (for instance two additional numbers 
and  one  primary  number).  Each  such  additional  number  may  be  configured  with  different  ringing 
parameters (ringtone and number of signals). 
If the primary numbers and additional numbers overlap, the latter have priority and calling in these 
cases  is  always  made  according  to  their  settings.  The  access  codes  are  the  codes  in  the  table, 
corresponding to the physical address of the receiver. 

Summary of Contents for FAM-P

Page 1: ...1 DOOR ENTRY SYSTEMS EXTENDED USER INSTRUCTION OF FAM P AND FAM PV DOOR ENTRY SYSTEMS 62 002 Suchy Las ul Diamentowa 7 tel fax 61 843 93 71 www aco com pl...

Page 2: ...ccess code 32 Modification of administrator s initial access code 33 2 SETTING E LOCK OPENING TIME 33 3 SETTING THE NUMBER OF RINGTONES PERMISSION TO CALL APARTMENT 33 4 TURNING ON OFF THE DOOR OPENIN...

Page 3: ...he opening code resident administrator 2 Setting E lock reset time 3 Setting the number of ringtones permission to call apartment 4 Turning the door opening signal off on 5 Setting one of four rington...

Page 4: ...c keypad while all settings are available via FAM_P computer program PC Windows Adding deleting archiving transferring between panels proximity fobs can be done using the ACC_v3 software PC Windows In...

Page 5: ...e customised to individual requirements Adjustable camera position in each direction FAM PV panels Option of image viewing in darkness infrared illumination FAM PV panels Support for proximity key fob...

Page 6: ...addresses from the bottom address 1 bottom button and successively up to address 6 top button It is also possible after changing the settings via the PC program or directly on the panel numeric keypa...

Page 7: ...d It is possible to open without having to connect with the apartment In this case on classic uniphones the handset must be picked up and the open button pressed three times on active receivers INS UP...

Page 8: ...ervice program 9 By default the code table is only added to panels FAM P ZS and FAM PV ZS For other versions of the panel use the code table that is used in the panel master panel or generate it using...

Page 9: ...sed for opening via an additional module such as an I O module The module is connected to the EXTMOD socket on the panel board and configured via the PC program Automatic opening when calling an addit...

Page 10: ...XI CDN U signalling module with opening function This module can be used to connect additional devices signalling ringing in the apartment for instance additional bells light bulbs signallers etc for...

Page 11: ...11 V MOUNTING AND CONNECTING THE PANEL ASSEMBLY The panel should be assembled so as to minimise the impact of adverse weather conditions in particular water Allen key 3 Allen key 3 Allen key 3...

Page 12: ...s where the camera lens may be exposed to direct perpendicular light from the sun street lamps etc 2 CONNECTING THE PANEL All connections in the installation must be soldered The following wires need...

Page 13: ...cross section with 1 mm2 wire the distance can be increased to 400 m with 1 5 mm2 wire the distance can be increased to 600 m with 2 5 mm2 wire the distance can be increased to 1000 m Use CDNV RJ45 m...

Page 14: ...number of receivers in the entire system detailed information can be found in the assembly instructions for the active receivers used In the case of video panels the wiring between the panel and the...

Page 15: ...stalled in the panel available under the panel terminals When working with reversible E locks voltage appears on ELOCK output depending on transformer or DC power supply used 15VDC use suitable revers...

Page 16: ...16 3 WIRING DIAGRAMS FOR SINGLE PANEL INSTALLATION Audio panel installation with passive receivers should be connected as per the diagram below Line Line Line Line...

Page 17: ...17 The installation of audio panels with active receivers should be connected as per the diagram below...

Page 18: ...18 The installations of audio panel with additional external camera and monitors should be connected as per the diagram below To monitor or splitter...

Page 19: ...ting the bus cable orange and brown together to DC terminal of the panel in this case the maximum distance between the panel and the monitor is 70m If the additional power supply is connected directly...

Page 20: ...20 Video Panel with several monitors should be connected as per the diagram below Rozdzielacz Splitter Rozdzielacz Splitter...

Page 21: ...he panel microphone using the MIC potentiometer adjust the panel speaker volume level using the SPK potentiometer As the MIC and SPK values are set turn the BALANCE potentiometer to determine the posi...

Page 22: ...of the busy panels Calling and connection topology of Slave panels is shown in the figure below where A is the Master panel B C D E F are Slave panels Only those receivers that are physically connect...

Page 23: ...he first Familio master panel If several Familio audio panels are installed two bus wires are arranged to the first panel Line Line and Line are connected to the ML terminal of the next panel Line to...

Page 24: ...or opening codes will be the same for all apartments For proper operation of a system with multiple panels configuration is required for the number and range of apartment addresses that a panel is to...

Page 25: ...25 Installation of multiple audio panels with active receivers should be connected as per the diagram below...

Page 26: ...multiple audio panels with additional external camera and multiple monitors should be connected as per the diagram below Rozdzielacz Splitter Kolejne pi tra Next floors Sumator bez kamery Intermediate...

Page 27: ...27 Installation with multiple video panels and monitors should be connected as per the diagram below Rozdzielacz Splitter Sumator po redni do FAM PV Intermediate combiner for FAM PV...

Page 28: ...mator po redni do FAM PV Intermediate combiner for FAM PV Rozdzielacz Splitter Rozdzielacz Splitter Rozdzielacz Splitter Sumator po redni do FAM PV Intermediate combiner for FAM PV Sumator bez kamery...

Page 29: ...er for FAM PV Klatka budynek X Staircase building X Kolejne pietra Next floors Kolejne pietra Next floors Klatka budynek Y Staircase building Y Rozdzielacz Splitter Sumator po redni do FAM PV Intermed...

Page 30: ...30 Installation with two panels the first of which is an Audio panel should be connected as per the diagram below example 4 Kolejne pietra Next floors Rozdzielacz Splitter...

Page 31: ...he panel such as individual access codes opening time ringtone etc Service programs are also available to facilitate installation and repairs Basic parameters can be changed using the service menu acc...

Page 32: ...LE To enter the panel programming function with 0000 installer s code press the key followed by 1507 fixed digits and 0000 1 5 0 7 0 0 0 0 Entering the programming mode is confirmed by an up modulated...

Page 33: ...ting time from 1s to 10s by entering a digit between 0 and 9 0 means 10 seconds When the panel is reset to factory settings the time is set to 4s 3 SETTING THE NUMBER OF RINGTONES PERMISSION TO CALL A...

Page 34: ...partment With the receiver s handset lifted press the door opening button three times for passive receivers or press the door opening button once for active receivers The panel will confirm receipt of...

Page 35: ...dents are set across the whole system For panels with only a numeric keypad the code table number is entered in accordance with the code table supplied Any code table can be generated and name tag pri...

Page 36: ...code Enabling the restriction of the administrator s code from 6 to 4 digits Doorman s call Enabling the doorman s call by shorting the INPUT Call only button Permitting calls only from direct call b...

Page 37: ...No 1 or 2 or 3 E lock triggering time as for standard opening Activation of the OUTPUT for a pre set time after pressing the F2 key on the uniphone or after selecting the code preceded by the double p...

Page 38: ...itional number 1 Address Physical address to which the panel will call after dialling the additional number Tone Ringtone in the apartment after dialling the additional number Number of ringtones Numb...

Page 39: ...e CDNP INSPIRO i e calls can be made directly from the numeric keypad and the codes must be preceded by the apartment number and the button of the button Once the factory settings are successfully res...

Page 40: ...surface causing abrasion of its natural protective coating and increasing the risk of corrosion XVI SAFETY RULES FOR INSTALLATION AND USE Installation should be carried out by a qualified installer B...

Page 41: ...12V between GND and ELOCK terminal Each panel in the system must feature a separate power supply Door opening signalled by the unit but E lock won t work Check E lock or E lock connection to the panel...

Reviews: