Opening with additional push button
The panel features an additional INPUT, which is configured by default as additional opening - when
shorted to ground it activates door opening. Such opening while the call is pending completes the
procedure of calling the apartment.
This input can be connected to any NO button such as INS-OB, code lock, card access reader,
motion detector etc. The input is protected against a permanent circuit short-circuit (short circuit
triggers it’s disconnection from the system until released).
Further door opening
The slave panel features the so called a further door opening function. If the master panel opens the
door and terminates the call or opens the door with an access code or proximity key fob, the waiting
time is automatically activated in the next slave panel. During this time, pressing any button (except
"#") activates door opening. This option is enabled only in those slave panels through where the call
originated or which must me used (passed) to reach the apartment assigned to the access code or
proximity key fob used. Standby mode can be cancelled with the "#" button. If the parameter "Open
after delay" is activated, after the pre-set delay time has passed the door will be opened automatically
without pressing any key. The wait time is set in each slave panel. The further door opening pulse
must be enabled on the master panels. The function is disabled in the panels' default settings and
can be enabled using the software.
Opening using the input from the additional module
The panel can be used for opening via an additional module, such as an I/O module. The module is
connected to the EXTMOD socket on the panel board and configured via the PC program.
Automatic opening when calling an additional number
If the "Auto door opener" function is enabled (for additional number only) and the handset is not hung
up (picked up), door opening will be activated automatically after the first ringing signal. If the handset
was hung up during the first ringing tone, the panel works normally - the handset can be picked up
and communication is possible. The automatic opening function is commonly used in commercial
buildings
- letting people in is done by simply lifting the handset; after business hours the handset is hung up
and the door entry unit works normally. For this purpose, the recommended receiver model is INS-
UP720B/XM. For certain active receivers (for example UP800/MP800/INS-MP7) it is possible to
activate the auto-opening function independently.
Additional numbers.
Two additional supported numbers can be added for the ringing operation mode using numeric
keypad buttons. These can be any number in the range of 1-999 (disabled by default), to which
physical addresses of receivers can be assigned. Additional numbers can assigned to the same
receiver so that it can be called using three different numbers (for instance two additional numbers
and one primary number). Each such additional number may be configured with different ringing
parameters (ringtone and number of signals).
If the primary numbers and additional numbers overlap, the latter have priority and calling in these
cases is always made according to their settings. The access codes are the codes in the table,
corresponding to the physical address of the receiver.