37
-
Description of
operation
Application
example
Settings
Remar
ks
Activation of the OUTPUT
for a pre-set time after
closing the INPUT
contacts
Gate control with third
wire from the receiver
(only INS- UP720M, INS-
UP720MR)
IN=0
OUT=t (t: time from 1 to 255
s) NrF=0
For P2 Port, the function
works only during a call
Activation of the OUTPUT
for a pre-set time
simultaneously with
triggering the E-lock
Automatic staircase light
switch on when door is
opened
IN=0
OUT=t (t: time from 1 to
255 seconds)
NrF=1
For P1 port, the function
works only for physical
addresses set in P24
Control of a second E-lock
with one control panel and
two doors
Activation of apartment
call procedure after
closing the INPUT
contacts
Direct uniphone call
(external direct call
button)
IN=y (y: receiver physical
address from 1 to 255)
OUT=x (x: has no effect)
NrF=1 or 2 or 3
Works for function No. 1 or
2 or 3
Activation of the E-lock after
closing the INPUT contacts
Activation of the E-lock
from an external push
button
IN=0
OUT=x (x: has no effect)
NrF=1 or 2 or 3
It works for function No. 1
or 2 or 3.
E-lock triggering time as
for standard opening
Activation of the OUTPUT
for a pre-set time after
pressing the F2 key on the
uniphone or after selecting
the code preceded by the
double pressing the key
button
Gate control using standard
two wires from the camera
and code from the keypad
IN=x (x: has no effect) OUT=t
(t: time from 1 to 255 s)
NrF=2
Control from
uniphone works only
during a call
Activating the E-
lock without making
a call
Pick up the handset and
press the "key" button three
times
For INS-UP720MR and
INS- MPR, press the
“key” button once without
lifting the handset
N=x (x: has no effect)
OUT=0
NrF=3
Works only for P1 port, no
need to connect the
CDN-I/O module
Activation of the OUTPUT
for a pre-set time without
making a call
Pick up the handset and
press the "key" button three
times
For INS-UP720MR and
INS- MPR, press the
“key” button once
IN=x (x: has no effect) OUT=t
(t: time from 1 to 255 s)
NrF=3
Works only for P1 port
Activation of the OUTPUT
for a pre-set time after
pressing any key on the
unit/panel or expansion
module
Automatic light switch on in
front of the entrance / on
the staircase
IN=x (x: has no effect) OUT=t
(t: time from 1 to 255 s)
NrF=3
Works only for P2 port
Example settings can be found in the table on the next page