ACME VQ80 Quick Start Manual Download Page 1

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR

INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1. Use this unit only in the manner intended by the manufac-

turer. If you have questions, contact the manufacturer at

the address or telephone number listed in the warranty.

2. Before servicing or cleaning unit, switch power off at ser-

vice panel and lock the service disconnecting means to pre-

vent power from being switched on accidentally. When the

service disconnecting means cannot be locked, securely

fasten a prominent warning device, such as a tag, to the

service panel.

3. Installation work and electrical wiring must be done by a

qualified person(s) in accordance with all applicable codes

and standards, including fire-rated construction codes and

standards.

4. Sufficient air is needed for proper combustion and exhaust-

ing of gases through the flue (chimney) of fuel burning equip-

ment to prevent backdrafting. Follow the heating equipment

manufacturer’s guideline and safety standards such as

those published by the National Fire Protection Association

(NFPA), and the American Society for Heating, Refrigera-

tion and Air Conditioning Engineers (ASHRAE), and the

local code authorities.

5. When cutting or drilling into wall or ceiling, do not damage

electrical wiring and other hidden utilities.

6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it must be

marked as appropriate for the application and be connected

to a GFCI (Ground Fault Circuit Interrupter) - protected

branch circuit.

8. Never place a switch where it can be reached from a tub or

shower.

9. This unit must be grounded.

CAUTION

1. For general ventilating use only. Do not use to exhaust haz-

ardous or explosive materials and vapors.

2. To avoid motor bearing damage and noisy and/or unbal-

anced impellers, keep drywall spray, construction dust, etc.

off power unit.

3. Please read specification label on product for further infor-

mation and requirements.

CEILING VENTILATOR/VENTILATEUR DE PLAFOND

MODEL / MODÈLE VQ80

TYPICAL INSTALLATIONS

HOUSING

CEILING

JOIST

MOUNTING TABS

GRILLE

CEILING

MATERIAL

POWER CABLE

HOUSING

CEILING

JOIST

MOUNTING TABS

GRILLE

CEILING

MATERIAL

POWER CABLE

4" ROUND

DUCT

ADDITIONAL

FRAMING

HOUSING MOUNTED TO ADDITIONAL FRAMING

Discharge 90

0

 to joists.

HOUSING MOUNTED DIRECTLY TO JOIST

2x6 (or larger) 

Discharge parallel to joists.

HOUSING

2 x 4

CEILING

JOIST or

TRUSS

MOUNTING

TABS

GRILLE

CEILING

MATERIAL

POWER CABLE

ADDITIONAL

FRAMING

2 x 4

CEILING

JOIST or

TRUSS

HOUSING MOUNTED TO 2x4 TRUSS

Requires additional framing for mounting tabs.

Discharge parallel to joists.

HOUSING

MOUNTING

TABS

GRILLE

CEILING

MATERIAL

POWER CABLE

ADDITIONAL

FRAMING

"

I

"

JOIST

"

I

"

JOIST

HOUSING MOUNTED TO “I” JOIST

Requires additional framing for mounting tabs.

Discharge parallel to joists.

HOUSING

2 x 4

CEILING

JOIST or

TRUSS

MOUNTING TABS

GRILLE

CEILING

MATERIAL

POWER CABLE

4" ROUND

DUCT

ADDITIONAL

FRAMING

2 x 4

CEILING

JOIST or

TRUSS

HOUSING MOUNTED TO 2x4 TRUSS

Requires additional framing for mounting tabs.

Discharge 90

0

 to joists.

HOUSING

MOUNTING TABS

GRILLE

CEILING

MATERIAL

POWER CABLE

4" ROUND

DUCT

ADDITIONAL

FRAMING

"

I

"

JOIST

"

I

"

JOIST

HOUSING MOUNTED TO “I” JOIST

Requires additional framing for mounting tabs.

Discharge 90

0

 to joists.

*

*

*

ACME ENGINEERING & MANUFACTURING CORP.

P.O. Box 978
Muskogee, Oklahoma 74402

READ AND SAVE THESE

INSTRUCTIONS

!

Installer: Leave this manual with the

homeowner.

Homeowner: Use and Care information

on page 4.

* Additional framing must be a 2x6 (minimum height), at

least 9-inches long.

LISEZ ET CONSERVEZ

CES DIRECTIVES

AVERTISSEMENT

AFIN DE DIMINUER LES RISQUES D’INCENDIE,

D’ÉLECTROCUTION OU DE BLESSURES, SUIVEZ CES

DIRECTIVES :

1. N’utilisez cet appareil que de la manière prévue par le

manufacturier. Pour toute question, adressez-vous à lui à

l’adresse ou au numéro de téléphone indiqués dans la

garantie.

2. Avant d’effectuer toute réparation ou nettoyage, coupez

le courant au panneau électrique et verrouillez le

disjoncteur afin d’éviter que le courant ne soit rétabli

accidentellement. Si le disjoncteur ne peut être verrouillé,

accrochez une affiche ou une étiquette bien en vue sur le

panneau.

3. L’installation et les branchements électriques doivent être

effectués par un personnel compétent, conformément aux

normes et aux codes en vigueur, y compris les normes et

les codes du bâtiment relatifs à la résistance au feu.

4. Assurez un apport d’air suffisant par un conduit de

cheminée pour la combustion et l’évacuation adéquates

des gaz de tout appareil à combustion d’huile afin de

prévenir tout refoulement des gaz, conformément aux di-

rectives du fabricant et aux consignes de sécurité publiées

par des organismes tels que la National Fire Protection

Association (NFPA), l’American Society for Heating, Re-

frigeration and Air Conditioning Engineers (ASHRAE), et

les autorités locales.

5. Lors du perçage ou du découpage d’un mur ou d’un

plafond, prenez garde de ne pas endommager le câblage

électrique ni aucune installation dissimulée.6. La  sortie

de tout conduit d’évacuation de ventilateur doit aboutir à

l’extérieur.

7. Si cet appareil doit être installé au-dessus d’une baignoire

ou d’une douche, il doit comporter les mentions

appropriées pour ces utilisations et être connecté à un

circuit protégé par un disjoncteur de fuite à la terre (GFCI).

8. Ne placez jamais un interrupteur de sorte que l’on puisse

l’atteindre d’une baignoire ou d’une douche.

9. Cet appareil doit être relié à une mise à la terre.

ATTENTION

1. Cet appareil ne convient qu’à des fins de ventilation

générale. Ne pas l’utiliser pour l’évacuation de matières

ou de vapeurs dangereuses ou explosives.

2. Pour éviter que les roulements du moteur ne soient

bruyants ou s’abîment, ou de déséquilibrer la roue à

ailettes, protégez l’appareil des poussières de placoplâtre

et de construction.

3. Veuillez lire l’étiquette des caractéristiques techniques du

produit pour de plus amples informations quant aux

exigences.

!

Installateur : Veuillez laisser ce manuel au

propriétaire.

Propriétaire : Voir le mode d’utilisation et

d’entretien à la page 4.

*

*