1. Safety Instructions   

 

 

WARNING 

 

 

Please keep this User Manual for future consultation. If you sell the fixture to another user, be 

sure that they also receive this instruction booklet. 

 

Unpack and check carefully there is no transportation damage before using the fixture. 

 

It’s important to ground the yellow/green conductor to earth in order to avoid electric shock. 

 

Disconnect main power before servicing and maintenance. 

 

Maximum ambient temperature is Ta: 40

. Don’t operate it where the temperature is higher 

than this. 

 

In  the  event  of  serious  operating  problem,  stop  using  the  fixture  immediately.  Never  try  to 

repair  the  fixture  by  yourself.  Repairs  carried  out  by  unskilled  people  can  lead  to  damage  or 

malfunction. Please contact the nearest authorized technical assistance center. Always use the 

same type spare parts. 

 

Do not connect the device to any dimmer pack. 

 

Do not touch any wire during operation and there might be a hazard of electric shock. 

 

To  prevent  or  reduce  the  risk  of  electrical  shock  or  fire,  do  not  expose  the  fixture  to  rain  or 

moisture. 

 

The housing must be replaced if they are visibly damaged. 

 

Do not look directly at the LED light beam while the fixture is on. 

 

There are no user serviceable parts inside the fixture. Do not open the housing or attempt any 

repairs by yourself. In the unlikely event your fixture may require service, please contact your 

nearest dealer. 

 

Due to the magnifying type lens, please keep the lens out of contact with direct sunlight. Direct 

sunlight can cause heat to build up inside of the unit, which will seriously damage unit. 

 

 

 

 

 

 

Please read the instructions carefully which includes important 

information about the installation, operation and maintenance. 

If using a 230Vac 50Hz power supply, do not connect in series more than 14 units, use another 
mains supply for the next 14 units. 
If using a 120Vac 60Hz power supply, do not connect in series more than 9 units, use another 
mains supply for next 9 units. 

 

Summary of Contents for VENOM LED-460

Page 1: ...VENOM LED 460 User Guide Please read the instruction carefully before use...

Page 2: ...Set the Fixture 4 4 1 Control Panel 4 4 2Main Function 5 5 How to Control the Unit 9 5 1 Master Slave Built In Preprogrammed Function 9 5 2 Easy Controller by CA 8 10 5 3 DMX Controller 10 6 DMX 512 C...

Page 3: ...uch any wire during operation and there might be a hazard of electric shock To prevent or reduce the risk of electrical shock or fire do not expose the fixture to rain or moisture The housing must be...

Page 4: ...Hz Power consumption 38 9W Fuse T 6 3A LED 6 x 3W Tri color LEDs 30000hrs rated Dimension 424 x 251 x 138mm Weight 3 8kgs 3 Installation The unit should be mounted via its screw holes on the bracket A...

Page 5: ...4 1 Control Panel 1 Display To show the various menus and the selected functions LED 2 DMX On DMX input present 3 MASTER On Master Mode 4 SLAVE On Slave Mode 5 SOUND Flashing Sound activation Button 6...

Page 6: ...ect to supply mains power for the next unit 16 Mains input Connect to supply mains power 4 2Main Function To select any of the given functions press the MENU button to show the required option on the...

Page 7: ...6A...

Page 8: ...ons without any change press the MENU button Show Mode Press the MENU button up to when the is shown on the display Pressing the ENTER button Use the DOWN and UP button to select the Random show or sh...

Page 9: ...ink Use the DOWN and UP button to select display on or display off mode Once selected press the ENTER button to setup or exit menu mode without any change after 60 seconds Back to the functions withou...

Page 10: ...rogrammed Function By linking the units in master slave connection the first unit will control the other units to give an automatic sound activated synchronized light show This function is good when y...

Page 11: ...on the display Press the ENTER button and the display will blink Use the DOWN and UP buttons to change the DMX512 address Once the address has been selected press the ENTER button to store To return t...

Page 12: ...11A 6 DMX 512 Configuration 3 Channels Mode 7 Channels Mode...

Page 13: ...12A 18 Channels Mode 7 DMX 512 Connection The DMX512 is widely used in intelligent lighting control with a maximum of 512 channels...

Page 14: ...n address set to receive the data sent by the controller The address number is between 0 511 usually 0 1 are equal to 1 5 3 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal 5 pin XLR Pin...

Page 15: ...ing the microphone E One of the channels is not working well 1 The stepper motor might be damaged or the cable connected to the PCB is broken 2 The motor s drive IC on the PCB might be out of conditio...

Page 16: ...nce with the provision of the Electromagnetic Compatibility EMC Directive 2004 108 EC EN55103 1 2009 EN55103 2 2009 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 Harmonized Standard EN 60598 1 200...

Page 17: ...16A Innovation Quality Performance...

Reviews: