Page 1: ...TS 150 CW TS 150 WW TS 1504 CW TS 1504 WW User Manual Please read the instruction carefully ...

Page 2: ...Barn Door Installation 4 4 How To Set The Unit 5 4 1 Control panel 5 4 2 Main Functions 6 5 How to Control the Unit 11 5 1 Master Slave Built In Preprogrammed Function 11 5 2 DMX Controller 11 5 3 DMX 512 Configurations 12 6 DMX 512 Connections 12 7 Troubleshooting 13 8 Fixture Cleaning 14 1D ...

Page 3: ...azard Use safety cable when fixes this unit DO NOT handle the unit by taking its head only but always by taking its base Maximum ambient temperature is Ta 40 DO NOT operate it where the temperature is higher than this Unit surface temperature may reach up to 85 DO NOT touch the housing bare hand during its operation Turn off the power and allow about 15 minutes for the unit to cool down before rep...

Page 4: ...ort a weight of 10 times of the unit s weight Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture The equipment must be fixed by professionals And it must be fixed at a place where is out of the touch of people and has no one pass by or under it 2 Technical Specifications The best price performance ratio LED theater spot engineered to exceed ...

Page 5: ...ght Source 1 150W white LED CRI WW 92 CW 89 Weight 8 6Kgs Dimension 406 417 238mm Photometric Diagram Distance m 3 5 7 10 14 Lux CW 6920 2300 1175 575 14 55 WW 6240 2380 1215 595 55 Lux CW 2240 820 420 205 WW 2000 840 430 210 3 The Plate for Color Filter Barn Door Installation Fig 1 4D ...

Page 6: ...for Color Filter into the inside slot from topsideA 3E A Fig 2 Secondly please insert the Barn Door into the outside slot from topside as arrow A 4E A and fasten the lock Note the Barn Door must be fastened into the inside of the lock s hook then flip down the lock cap again as arrowA 5E A 4 How To Set The Unit 4 1 Control panel 5D ...

Page 7: ...OUT Connects to the next unit 9 DMX output For DMX512 link use 5 pin XLR cable to link the unit together 10 Fuse T5A Used to protect the unit from damage of the over current 11 Power Switch Used to turn On Off the fixture 4 2 Main Functions To select any functions press the MENU button until the required one is shown on the display Select the function by ENTER button and the display will blink Use...

Page 8: ...7D ...

Page 9: ... ENTER button to save Hold and press the MENU button about one second or wait for one minute to exit the menu mode Dimmer Curve To select Dimmer Curve press the ENTER button to show the DIMMER CURVE on the display use the UP DOWN button to select Mode 1 Mode 2 Mode 3 or Mode 4 Once selected press the ENTER button to store Press the MENU button back to the last menu or let the unit idle one minute ...

Page 10: ...n to confirm use UP DOWN button to select Backlight Intensity Contrast Ratio Backlight Auto Off Display Inverse or Language Backlight Intensity Select Backlight Intensity press the ENTER button to confirm present mode will blink on the display use the UP DOWN button to adjust backlight intensity from 1 dark to 10 bright press the ENTER button to save Press the MENU button back to the last menu or ...

Page 11: ... MENU button back to the last menu or let the unit idle one minute to exit menu mode Manual Test Select Manual Test press the ENTER button to confirm Use the DOWN and UP button to select the Zoom Position or Dimmer Value mode Once selected use the DOWN and UP button to adjust the value 0 255 and press the ENTER button to save Press the MENU button back to the last menu or let the unit idle one min...

Page 12: ...d the fixture will now reset 5 How to Control the Unit You can operate the unit in two ways 1 Master slave built in preprogram functions 2 Universal DMX controller 5 1 Master Slave Built In Preprogrammed Function By linking the units in master slave connection the first unit will control the other units to give an automatic synchronized light show This function is good when you want an instant sho...

Page 13: ... for the first 4 units 2 channels 5 3 DMX 512 Configurations 2 Channels Mode CHANNEL VALUE FUNCTION 1 0 255 DIMMER 0 100 2 0 255 ZOOM 6 DMX 512 Connections The DMX512 is widely used in intelligent lighting control with a maximum of 512 channels 1 Connect the fixture together in a daisy chain by XLR plug cable from the output of the fixture to the input of the next fixture The cable cannot be branc...

Page 14: ...1 GND Pin 2 Negative signal Pin 3 Positive signal 5 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal Pin4 5 not used 7 Troubleshooting Following are a few common problems that may occur during operation Here are some suggestions for easy troubleshooting A The unit does not work no light and the fan does not work 1 Check the connection of power and main fuse 2 Measure the mains voltage...

Page 15: ...l and external optical lenses and or mirrors must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at ...

Page 16: ... the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 EN55103 2 2009 EN62471 2008 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 1BHarmonized Standard EN 60598 1 2008 All 2009 EN 60598 2 17 1989 A2 1991 EN 62471 2008 EN 62493 2010 Safety of household and similar electrical appliances Part 1 General requirements Innovation Quality Performance 15D ...