REED A40HP Quick User Guide

 

pg 1

Turn on the Key Switch.

Pull out the Emergency Stop (E-Stop) Switch.

Push and hold the Start Button to start the 

engine.

Turn on the Horn Switch to deactivate the 

E-Stop Light. If the E-Stop Light is 

ON

, the 

pump will not operate.

Ensure that the Forward/Reverse Switch is at 

FWD.

Start pumping by turning on the Pump 

Switch. The S-Tube will start turning.

1.

2.

3.

4.

5.

6.

Starting the Pump

Turn off the Pump Switch.

Turn the Forward/Reverse Switch to REV.

Turn on the Pump Switch to start reversing 

and removing the pressure.

Continue reversing until the Drive Cylinder 

Pressure Gauge reaches 0 before 

dismantling. 

DO NOT

 

open the outlet & pipes 

if there’s any pressure shown in pressure 

gauge.

1.

2.

3.

4.

Pumping in Reverse

Control Panel:

1. Hour Meter

2. Emergency Stop (E-Stop) Button

3. Start Button

4. Key Switch

5. Remote/Local Control Mode Switch

6. High/Low RPM Switch

7. Horn Switch

8. Pump Switch

9. Forward/Reverse Switch

10. Stroke Change Switch

2

3

4

5

7

9

1

6

8

10