Caution: 

There are no user serviceable parts inside the unit. Do not open the housing or attempt any 

repairs yourself. In the unlikely event your unit may require service, please contact your nearest 

dealer.

 

Installation: 

The unit should be mounted via its screw holes on the bracket.  Always ensure that the unit is 

firmly fixed to avoid vibration and slipping while operating. Make sure that the structure to which 

you are attaching the unit is secure and is able to support a weight of  10 times of the unit’s 

weight. Also always use  a safety cable that can hold 12 times of the weight of the unit when 

installing the fixture.   

The equipment must be installed by professionals. It must be fixed at a place where is out of the 

reach of people and no one pass by or under it. 

 

  2. Technical Specifications   

 

Theatre LED Flood is a powerful cyclorama projector,with innovative optics,featuring high 
power quad color LED and 90°x 113°beam angle, delivering excellent color mixing, even and 
wide-field projection. 

 

Control Mode: DMX, Master/Slave 

 

DMX Channel: 4 / 9 Channels 

 

0~100% smooth dimming 

 

Color frame for use of color filters and barn doors included 

 

Variable strobe speed 

 

LCD display for easy navigation 

 

Power Voltage:  

            AC 100 ~ 240V, 50/60Hz 

 

Power Consumption: 

        155W 

 Light Sources:               

1

 

x 150W RGBW LEDs 

 

Beam angle: 

               90

°

x 113

°

 

 

Weight:   

                 6.2 Kgs 

 

Dimension:  

                    425 x 364 x 419mm 

 

3B 

Summary of Contents for CYC-200 FC

Page 1: ...User Manual Please read the instruc on carefully before use CYC 200 FC...

Page 2: ...ture 4 3 1 Control Panel 4 3 2 The Plate for Color Filter Barn Door Installation 5 3 3 Main Function 6 4 How To Control The Unit 10 4 1 Master Slave Function 10 4 2 DMX Controller 10 4 3 DMX512 Config...

Page 3: ...close to the unit while operating as it is fire hazard Use safety cables when fixing this unit Maximum ambient temperature is Ta 40 degrees C DO NOT operate it where the temperature is higher than thi...

Page 4: ...he weight of the unit when installing the fixture The equipment must be installed by professionals It must be fixed at a place where is out of the reach of people and no one pass by or under it 2 Tech...

Page 5: ...Panel 4 1 Display Shows the various menus and the selected functions 2 DMX IN For DMX 512 link use 5 pin XLR cable to link the unit to a DMX controller 3 POWER IN Connects to mains supply power 4 POW...

Page 6: ...ns ENTER To confirm the selected functions 8 Fuse T3 15A To protect the unit from damage of over current 3 2 The Plate for Color Filter Barn Door Installation Please insert the Barn Door into the outs...

Page 7: ...ink Use the DOWN UP buttons to change the mode Once the required mode has been selected press the ENTER button to confirm To go back to the main functions without any changes press the MENU button aga...

Page 8: ...xit menu mode View DMX Value To select View DMX Value press the ENTER button to confirm Use the UP DOWN button to select Red Green Blue or White mode press the ENTER button to store Press the MENU but...

Page 9: ...UP DOWN button to select the No normal display or Yes inverse display press the ENTER button to save Press the MENU button back to the last menu or let the unit idle one minute to exit menu mode Backl...

Page 10: ...Use Time LED Temp or Firmware Version Fixture Use Time To select Fixture Use Time press the ENTER button to confirm and running time of the fixture will show on the display Press the MENU button back...

Page 11: ...ler to control the units you have to set DMX address from 1 to 512 so that the units can receive DMX signal Press the MENU button to enter menu mode select DMX Functions press the ENTER button to conf...

Page 12: ...WHITE 0 100 5 000 001 006 007 013 014 020 021 027 028 034 035 041 042 048 049 055 056 062 063 069 070 076 077 083 084 090 091 097 098 104 COLOR MACRO Open LEE 790 Moroccan Pink LEE 157 Pink LEE 332 Sp...

Page 13: ...LEE 088 Lime Green LEE 100 Spring Yellow LEE 104 Deep Amber LEE 179 Chrome Orange LEE 105 Orange LEE 021 Gold Amber LEE 778 Millennium Gold LEE 135 Deep Gold Amber LEE 164 Flame Red 6 000 041 042 083...

Page 14: ...high speed signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 3 The DMX output and input connectors are pass through to m...

Page 15: ...revious one 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit C One of the c...

Page 16: ...in accordance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 EN55103 2 2009 EN62471 2008 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 1BHarmonize...