4. How To Control The Unit
You can operate the unit in two ways:
1. By master/slave function
2. By DMX controller
You do not need to turn the unit off when you change the DMX address, the new DMX address
setting will take effect immediately.
4.1 Master/Slave Function
By linking the units in master/slave connection, the first unit will be master automatically. You
should set the master unit effect via its knobs, then the other units (slave) will lighting as the
same.
4.2 DMX Controller
If you use a universal DMX controller to control the units, you have to set DMX address from 1 to
512 so that the units can receive DMX signal.
Press the
MENU
button to enter menu mode, select
DMX Functions
, press the
ENTER
button to
confirm, use the
UP/DOWN
button to select
DMX Address
, press the
ENTER
button to confirm,
the present address will blink on the display. Use the
UP/DOWN
button to adjust the address from
1 to 512, press the
ENTER
button to store. Press the
MENU
button back to the last menu or let the
unit idle one minute to exit menu mode.
Please refer to the following diagram to set the address for the first 4 units.
Channel mode
Unit 1
Address
Unit 2
Address
Unit 3
Address
Unit 4
Address
4 channels
1
5
9
13
9 channels
1
10
19
28
10B