ACME CP-18TC User Manual Download Page 1

 

 

 

STAGE TRI-PAR 18TC 

 

 

 

 

 

 

 

 

CP-18TC 

 

 

     

       

                  User Manual 

                                  Please read the instructions carefully before use 

Summary of Contents for CP-18TC

Page 1: ...STAGE TRI PAR 18TC CP 18TC User Manual Please read the instructions carefully before use ...

Page 2: ... TABLE OF CONTENTS 1 Safety Instructions 2 Technical Specifications 3 How to Set the Fixture 4 How to Control the Fixture 5 DMX 512 Configuration 6 DMX 512 Connections 7 Troubleshooting 8 Fixture Cleaning ...

Page 3: ...overheated Before operating ensure that the voltage and frequency of power supply match the power requirements of the unit It s important to ground the yellow green conductor to earth in order to avoid electric shock Maximum ambient temperature TA 40 Don t operate it where the temperature is higher than this Don t connect the device to any dimmer pack First run there will be smoke or smells and al...

Page 4: ...authorized technical assistance center Disconnect the mains power if the fixture is not used for a long time Do use original packing materials once transport it again Do not look directly at the LED light beam while the fixture is on Installation The unit should be mounted via its screw holes on the bracket Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating...

Page 5: ... Fuse T 6 3A Power consumption 69W Dimension 224 x290 x362 mm Weight 2 7 kg 3 How to Set the Fixture 3 1 Control Panel 1 Display To show the various menus and the selected functions 2 LED DMX On DMX input present MASTER On Master Mode SLAVE On Slave Mode SOUND Flashing Sound activation ...

Page 6: ...For DMX512 link use 3 5 pin XLR plug cable to input DMX signal 7 Mains input Connect to supply mains power for the unit 3 2 Main Function To select any functions press MENU button until the required one is shown on the display Select the function by ENTER button and the display will blink Use DOWN and UP button to change the mode Once the required mode has been selected press ENTER button to setup...

Page 7: ... Inversion Normal Slave Mode 1 16 Blackout Mode No Blackout Blackout Mode Yes Blackout LED off LED on Fixture Hours Software Version Sound Mode on Sound Mode off Auto Setting DMX512 Address Chase Color Macro Temperature ...

Page 8: ...MENU button Note In RC8 mode the fixture will run the effect in RC8 controller Show Mode Press the MENU button up to when the is shown on the display Pressing ENTER button Use DOWN and UP button to select the Random show or show 1 or Show 2 or or show 12 once the show has been selected press ENTER button to confirm and use DOWN and UP button to adjust the speed speed 1 or or speed 8 Once the speed...

Page 9: ...he functions without any change press the MENU button Blackout mode Press the MENU button up to when the is shown on the display Pressing ENTER button Use DOWN and UP button to select the blackout or normal Once select press ENTER button to setup or automatically exit menu mode without any change after one minute To go back to the functions without any change press the MENU button Color mode Press...

Page 10: ...e display will show the temperature of the unit To go back to the functions press the MENU button again White Balance Press the MENU button up to when the is shown on the display Pressing ENTER button and use DOWN and UP button to select or press ENTER button to confirm and use DOWN and UP button to adjust the value between 125 and 255 once select press ENTER button to setup or automatically exit ...

Page 11: ...ose DMX input jack has with nothing connect will be master automatically set other units to slave 1 or slave2 or slave 16 via menu then the first unit will control the others to give an automatic sound activated synchronized light show This function is good when you want an instant show Any fixture can act as a Master or as a Slave 16 light show In slave mode slave 1 means the unit works as master...

Page 12: ... have to set DMX address from 1 to 512 channel so that the units can receive DMX signal Press the MENU button up to when the is showing on the display Pressing ENTER button and the display will blink Use DOWN and UP button to change the DMX512 address Once the address has been selected press and keep ENTER button pressed up to when the display stops blinking or storing automatically one minute lat...

Page 13: ...ound Open 0 7 8 190 191 200 201 247 248 255 Mode1 CH 1 CH2 CH3 CH4 Red Green Blue Dimmer Mode2 Fast Slow Mode 3 4 DMX512 Configuration CH 1 CH2 CH3 CH4 Red Green Blue Dimmer Strobe 0 160 161 255 Mode3 CH 1 CH2 CH3 CH4 Red Green Blue Dimmer Mode4 Fast Slow 0 127 200 255 Fast Fast Slow Slow 128 199 Color Macro ...

Page 14: ...147 Color18 132 139 Color17 124 131 Color16 117 123 Color15 109 116 Color14 101 108 Color13 093 100 Color12 086 092 Color11 078 085 Color10 070 077 Color9 062 069 Color8 055 061 Color7 047 054 Color6 039 046 Color5 031 038 Color4 024 030 Color3 016 023 Color2 008 015 Color1 000 007 OFF Color Dimmer Ch5 Open Open 132 139 140 181 191 231 240 247 Random strobe Slow Close Fast Open Slow Open Fast Clos...

Page 15: ... the last fixture 4 Each lighting fixture needs to have an address set to receive the data sent by the controller The address number is between 0 511 usually 0 1 are equal to 1 5 3 pin XLR connectors are more popular than 5 pins XLR 3 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal 5 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal Pin4 5 not used 7 Troubleshooting Follo...

Page 16: ...does not receive DMX signal 2 Check microphone to see if it is good by tapping the microphone E One of the channels is not working well 1 The stepper motor might be damaged or the cable connected to the PCB is broken 2 The motor s drive IC on the PCB might be out of condition 8 Fixture Cleaning The cleaning of internal must be carried out periodically to optimize light output Cleaning frequency de...